Supreme 10HT, 10HTCL, 10HTF-1, 10HTND-3 one-component toughened hot-cure epoxies (from 4 K to +204 °C)

The flagship one-component toughened hot-cure epoxy system, with a shear strength of 24.8–26.2 MPa, working from 4 K to +204 °C. It needs no mixing and no freezing. It is used for structural bonding in aerospace, electronics, optics and specialty machine building.

Type
one-component toughened epoxy (not a frozen premix), unlimited pot life at room temperature
Cure
Supreme 10HT 60–75 min at 121 °C or 35–40 min at 149 °C; 10HTF-1 5–10 min at 149 °C or 15–20 min at 121 °C
Shear strength
Supreme 10HT 24.8–26.2 MPa (3600–3800 psi); 10HTF-1 > 22 MPa; 10HTCL 19.3–20.7 MPa
Tensile strength of 10HTND-3
55–62 MPa

Technical specifications

Typeone-component toughened epoxy (not a frozen premix), unlimited pot life at room temperature
CureSupreme 10HT 60–75 min at 121 °C or 35–40 min at 149 °C; 10HTF-1 5–10 min at 149 °C or 15–20 min at 121 °C
Shear strengthSupreme 10HT 24.8–26.2 MPa (3600–3800 psi); 10HTF-1 > 22 MPa; 10HTCL 19.3–20.7 MPa
Tensile strength of 10HTND-355–62 MPa
Tg of Supreme 10HT130–135 °C
Operating temperaturefrom 4 K to +204 °C
Viscosity10HTCL 140 000–200 000 mPa·s; 10HT > 500 000 mPa·s; 10HTND-3 non-sag paste
CertificationsASTM E595 for Supreme 10HT, 10HTCL

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Supreme 10HT is a true one-component system with no freezing and unlimited pot life at room temperature. Curing starts only on heating, 60–75 minutes at 121 °C or 35–40 minutes at 149 °C. Shear strength is 24.8–26.2 MPa, the range is from 4 K to +204 °C, Tg 130–135 °C, and ASTM E595 compliance is confirmed. Supreme 10HTCL with a viscosity of 140 000–200 000 mPa·s has the same range and a volume resistivity above 10¹⁴ Ω·cm. Supreme 10HTF-1 is a fast paste that cures in 5–10 minutes at 149 °C or 15–20 minutes at 121 °C with a post-cure of 1–2 hours at 121–149 °C, shear above 22 MPa and modulus of 2.4–2.8 GPa. Supreme 10HTND-3 does not sag during heating and has a tensile strength of 55–62 MPa.

How to choose

Base Supreme 10HT suits cases that need the highest shear strength. For a fast cycle, 5–10 minutes at 149 °C, take 10HTF-1, and where the adhesive must stay on a vertical surface during heating, 10HTND-3. The less viscous 10HTCL, 140 000–200 000 mPa·s, spreads better. The series also includes thermally conductive 10AOHT and 10ANHT, nickel-filled and elasticized versions.

Request a price and lead time

Supreme 10HT, 10HTCL, 10HTF-1, 10HTND-3 one-component toughened hot-cure epoxies (from 4 K to +204 °C). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How does one-component Supreme 10HT differ from a frozen premix?

It is not a pre-mixed frozen composition, so its pot life at room temperature is unlimited. Curing starts only on heating.

How does Supreme 10HT cure?

60–75 minutes at 121 °C or 35–40 minutes at 149 °C. The glass transition temperature is 130–135 °C.

What is the shear strength of Supreme 10HT?

24.8–26.2 MPa (3600–3800 psi). For 10HTF-1 above 22 MPa, for 10HTCL 19.3–20.7 MPa.

What is the temperature range of Supreme 10HT?

From 4 K to +204 °C. The system meets ASTM E595 and withstands severe thermal cycling, impact and vibration.

What is the viscosity of Supreme 10HTCL?

140 000–200 000 mPa·s, which is much lower than Supreme 10HT with a viscosity above 500 000 mPa·s.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.