FRENIC-MEGA (G2) — general-purpose frequency converter 0.4–710 kW, 200/400 V

The general-purpose frequency converter FRENIC-MEGA (G2) controls low voltage motors from 0.4 to 630 kW, and in some versions up to 710 kW, in three-phase 200 and 400 V networks. It is used on pumps, fans, HVAC and water supply systems, conveyors, cranes and process machinery.

Motor power
0.4–630 kW (up to 710 kW in some versions); in the USA from 1/2 to 1200 hp
Supply
3-phase 200 V and 400 V (in the USA 230 and 460 V)
Load modes
HHD (heavy duty) and HND (normal duty); 400 V HHD 75–630 kW
Starting torque
≥ 200 % (up to 22 kW), ≥ 180 % (from 30 kW)

Technical specifications

Motor power0.4–630 kW (up to 710 kW in some versions); in the USA from 1/2 to 1200 hp
Supply3-phase 200 V and 400 V (in the USA 230 and 460 V)
Load modesHHD (heavy duty) and HND (normal duty); 400 V HHD 75–630 kW
Starting torque≥ 200 % (up to 22 kW), ≥ 180 % (from 30 kW)
Motorsinduction and synchronous (permanent magnet)
Controlsensorless vector and with speed sensor
Versionsbasic, with built-in EMC filter, with zero-phase reactor, with DC reactor
Functionsprogrammable logic (Customization Logic), functional safety, network interfaces
EMCexternal filter EN 61800-3 cat. C2 (up to 22 kW)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Starting torque is at least 200 % for models up to 22 kW and at least 180 % from 30 kW, so a machine starts under load without oversizing the drive. The unit controls induction motors and permanent magnet synchronous motors, with sensorless vector control or with a speed sensor. Compared with the previous generation, the control range is wider and control quality is improved. The Customization Logic function holds many more program steps, it is written through a PC loader, and on simple installations a separate controller is often unnecessary. Network interfaces and standardised safety functions simplify integration into a process control system, and data under the Ecodesign Directive is published. For setup from a phone there is the FRENIC Mobile Loader app.

How to choose

The frame size is chosen by motor current and load type. A pump or fan is fine in normal duty HND, while cranes, conveyors and machines with a heavy start need HHD, which at 400 V runs from 75 to 630 kW. Versions are basic, with a built-in EMC filter, with a zero-phase reactor or with a DC reactor. For rolling mills and lines with a common DC bus, FRENIC4400 inverters of 690–2100 kVA per unit or FRENIC4000 up to 300 kVA are more appropriate.

Request a price and lead time

FRENIC-MEGA (G2) — general-purpose frequency converter 0.4–710 kW, 200/400 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Does the FRENIC-MEGA (G2) work with permanent magnet synchronous motors?

Yes, they are supported as standard, along with induction motors. A speed sensor is fitted when accuracy at low speed is needed, otherwise sensorless vector control is enough.

Is the FRENIC-MEGA (G2) available in 230 and 460 V versions?

Yes, in North America the series is offered for motors from 1/2 to 1200 hp at 230 and 460 V.

How to get EN 61800-3 category C2 compliance for the FRENIC-MEGA (G2)?

For converters up to 22 kW the manufacturer supplies an external EMC filter, with which the drive complies with category C2.

Can a separate PLC be avoided with the FRENIC-MEGA (G2)?

On simple machines yes, since Customization Logic runs user logic right in the converter. Network interfaces provide the link to the upper level.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.