Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

2.RZKIT — low-voltage induction motor for operation from a frequency converter, 18.5–2500 kW

The 2.RZKIT squirrel-cage induction motor is intended for variable-speed drives fed from a frequency converter and covers powers from 18.5 to 2500 kW. Rated voltage is 230–690 V, mains frequency 50 or 60 Hz. Typical loads are pumps and fans with flow control, compressors, conveyors, extruders and mixers.

Designation
2.RZKIT
Rotor type
squirrel-cage
Power
18.5–2500 kW
Voltage / frequency
230–690 V / 50 Hz, 60 Hz

Technical specifications

Designation2.RZKIT
Rotor typesquirrel-cage
Power18.5–2500 kW
Voltage / frequency230–690 V / 50 Hz, 60 Hz
Shaft height (frame size)200–630
Number of poles2–8
Insulation classF / B
Protection degreeIP55
CoolingIC 411
MountingIM B3, B5, V1
Connection dimensionsIEC 60072
StandardIEC 60034-1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The series is built on frame sizes with a shaft height from 200 to 630 and a number of poles from 2 to 8. The design is closed, IP55, with IC 411 self-ventilation from an impeller on its own shaft. Class F winding insulation works with a temperature rise within class B, and this reserve absorbs additional losses from higher current harmonics and the stress on turn insulation from the steep voltage fronts of the inverter. The motor is supplied foot-mounted IM B3, flange-mounted IM B5 or in the vertical IM V1 version. Connection dimensions to IEC 60072 and the general requirements of IEC 60034-1 simplify replacing a machine from another manufacturer in an existing drive without reworking the foundation or half-couplings. The change from throttling to frequency control on pumps and fans noticeably reduces energy consumption. The series is used in metallurgy, mining and chemical industry, water supply and wastewater.

How to choose

The main question in selection concerns the control range and the nature of the load. In long operation at low speed with constant torque, IC 411 self-ventilation weakens, so the thermal regime is checked by calculation, and an independent fan and insulated bearings are agreed with the factory using the questionnaire. If the drive runs from the mains without a converter, it is more sensible to take the IE3 3.ZKE at 18.5–1000 kW. Machines with an IC 611 heat exchanger at 400–2500 kW are separated into the special 2.RZKIT…ic6 version.

Request a price and lead time

2.RZKIT — low-voltage induction motor for operation from a frequency converter, 18.5–2500 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How does the 2.RZKIT differ from a mains-fed induction motor?

The series is designed for supply from a frequency converter. Class F insulation with a temperature rise within class B covers additional losses from harmonics and the inverter's pulse stress on turn insulation.

Is an independent fan needed for the 2.RZKIT at low speeds?

The standard IC 411 cooling depends on shaft speed, so in long operation at low frequency with constant torque the temperature rise is checked. An independent fan is ordered if the calculation shows overheating.

What network is the 2.RZKIT motor designed for?

Rated voltage is 230–690 V, mains frequency 50 or 60 Hz. The motor voltage is selected to match the output voltage of the frequency converter.

What is the maximum power of the 2.RZKIT motor?

The upper limit of the series is 2500 kW at a shaft height up to 630, the lower one 18.5 kW. The mains-fed 3.ZKE series ends at 1000 kW, so for large variable-speed drives the 2.RZKIT is taken.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.