A-TEST - self-test system for emergency luminaires and the 50 TE controller
Country: Spain · Model: A-TEST / 50 TE
A-TEST is an automatic self-test system for emergency luminaires and signs that performs a functional test every 30 days and an autonomy test every 3 months. Staff do not need to check each luminaire manually, and the result is shown by a two-colour indicator on the enclosure itself.
- Functional test
- every 30 days
- Autonomy test
- every 3 months
- Indication
- two-colour LED
- Controller
- 50 TE - manual test, schedule setting
Technical specifications
| Functional test | every 30 days |
|---|---|
| Autonomy test | every 3 months |
| Indication | two-colour LED |
| Controller | 50 TE - manual test, schedule setting |
| Standards | EN 60598-2-22, EN 62034 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Luminaires with index A in the D-ecoLD, ecoLD, eco-esLD and VDC series have a built-in microprocessor that simulates a mains failure on a schedule. The functional test is performed every 30 days and checks changeover to emergency mode, the LEDs and the electronics. The autonomy test runs every 3 months and shows whether the battery holds the declared time. Battery charging takes 24 h. The state of the luminaire and the result of the last test are shown by a two-colour LED indicator. Depending on the model, Ni-Cd, Ni-MH or LiFePO4 is used, with Ni-MH in D-ecoLD and ecoLD with self-test, and LiFePO4 in VDC signs with self-test. The 50 TE controller makes it possible to start tests manually and set the time of automatic ones, non-maintained models connect to it, and maintained ones if they have the letter T in the designation. The system complies with EN 60598-2-22 for emergency lighting luminaires and EN 62034 for battery-powered automatic test systems. It is used in offices, schools, hotels, commercial and residential buildings.
How to choose
A model with self-test is chosen by the index A in the designation, for example D-ecoLD 130 A, D-ecoLD P220 A or ecoLD 80 A. VDC signs with self-test are fitted with LiFePO4 batteries for 1, 2 or 3 h, and D-ecoLD and ecoLD luminaires with self-test have Ni-MH. For remote starting of tests the 50 TE controller is added, and for maintained models the letter T is needed in the designation.
Request a price and lead time
A-TEST - self-test system for emergency luminaires and the 50 TE controller. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How often does A-TEST check emergency luminaires?
The functional test runs every 30 days and the autonomy test every 3 months.
What does the autonomy test check?
It shows that the battery holds the declared operating time of the luminaire in emergency mode.
How long does the battery in a luminaire with self-test take to charge?
The battery charging time is 24 h.
What is the 50 TE controller for?
It makes it possible to start tests manually and set the time of automatic ones. Non-maintained models are connected to it, and maintained ones if they have the letter T.
How can the test result be understood on the luminaire itself?
The state and the result of the last test are shown by a two-colour LED indicator.