SACIGEST / TTIGEST energy monitoring and consumption metering software

The SACIGEST and TTIGEST programs collect and display data from networks of meters and analyzers. SACIGEST manages terminals in the electrical network, and TTIGEST keeps metering of water, gas and electricity by customer for hotels, ports and rented offices and generates invoices. They work in Normal, Server and Client versions over Ethernet.

SACIGEST 01
monitoring and configuration of terminals
SACIGEST 02
+ energy by terminals and sections, up to 6 tariffs
SACIGEST 03
+ archive of currents, voltages, powers
Modes
Normal, Server, Client (client-server over Ethernet)

Technical specifications

SACIGEST 01monitoring and configuration of terminals
SACIGEST 02+ energy by terminals and sections, up to 6 tariffs
SACIGEST 03+ archive of currents, voltages, powers
ModesNormal, Server, Client (client-server over Ethernet)
Communicationup to 4 communication ports, modem
TTIGESTmetering of water, gas, electricity and invoicing; prepayment; load profiles from TTIM

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

In SACIGEST the installation is divided into sections, each with its own mimic diagram, and virtual terminals can be created from the real ones. The program works with the analyzers AHM3, ANG96, MAR, TMC, TMCQ, TMCC, CP3000, CP4000, and through TTI terminals with the meters M1DL-MID, M1DL1, M2DL2, M1DM1, M2DM1, TCIDL1, TCIL1. It supports up to 4 communication ports, a modem and client-server mode over Ethernet. SACIGEST 01 configures terminals, 02 adds energy graphs by terminals and sections with 6 tariffs, and 03 adds an archive of currents, voltages and powers. TTIGEST is compatible with the TTI-TTIM summators, the MAR144 analyzers and the meters M2DL2, M1DL2, M1DL3, TCIDL-MID. Metering is done by customer with check-in and check-out, automatic meter reading, prepayment and uncontrolled consumption, but it is not an accounting system. With TTIM, load profiles are built in tables and graphs with printing and export.

How to choose

The SACIGEST version is chosen by the required depth of data. The first only monitors and configures, the second adds energy metering with tariffs, and the third also an archive of currents, voltages and powers. The Normal, Server and Client sub-versions distinguish standalone operation from the client-server scheme over Ethernet. TTIGEST is taken where invoices must be issued to tenants, and load profiles require TTIM summators.

Request a price and lead time

SACIGEST / TTIGEST energy monitoring and consumption metering software. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What SACIGEST versions exist and how do they differ?

SACIGEST 01 configures terminals, 02 adds energy metering with up to 6 tariffs, and 03 adds an archive of currents, voltages and powers. Each version has Normal, Server and Client sub-versions.

Which instruments does SACIGEST work with?

With the analyzers AHM3, ANG96, MAR, CP3000, CP4000 and others, and through TTI terminals with the meters M1DL-MID, M2DL2, TCIDL1 and TCIL1.

Does TTIGEST replace an accounting program?

No, it keeps consumption metering by customer and generates invoices, but it is not an accounting system.

How many communication ports does SACIGEST support?

Up to 4 communication ports, as well as a modem and client-server mode over Ethernet.

Similar products

Software

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.