Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INDUSTRIAL FANS

THT, THT/CL, THT/IE5 axial smoke extraction fans F400/F300 (400 °C/2 h), up to ~199 000 m³/h

Ducted axial smoke extraction fans THT, THT/CL and THT/IE5, approved to EN 12101-3 in classes F400 (400 °C for 2 hours) and F300 (300 °C for 2 hours). Impeller diameter 400–1600 mm, the largest models deliver up to 199 000 m³/h. They work directly in the fire zone and ventilate the building every day in normal mode.

Type
ducted axial smoke extraction fan, operation in the fire zone (immersed)
Fire resistance
F400 (400 °C/2 h) and F300 (300 °C/2 h) per EN 12101-3, certificate 2797 CPR 840443
Impeller diameter
400–1600 mm (sizes 40–160, per the THT/CL datasheet)
Motor power
0.55–75 kW per datasheet table; IE4 for 75–200 kW (per series description)

Technical specifications

Typeducted axial smoke extraction fan, operation in the fire zone (immersed)
Fire resistanceF400 (400 °C/2 h) and F300 (300 °C/2 h) per EN 12101-3, certificate 2797 CPR 840443
Impeller diameter400–1600 mm (sizes 40–160, per the THT/CL datasheet)
Motor power0.55–75 kW per datasheet table; IE4 for 75–200 kW (per series description)
Maximum airflowup to ~199 000 m³/h (THT/CL-160, per datasheet)
Motorclass H, S1 continuous duty, S2 emergency duty; IP55; 1 or 2 speeds; IE3 from 0.75 kW, IE5 in THT/IE5
Power supply3~ 230/400 V 50 Hz (up to 3 kW), 400/690 V 50 Hz (above 3 kW)
Handled air temperature, S1−25…+40 °C (up to +50 °C permitted)
Impellercast aluminium, adjustable blade angle; 100% reversible on request
Coatingpolyester powder paint, cured at 190 °C
VersionsTHT: short casing; THT/CL: long casing with external terminal box and access hatch; THT/IE5, THT/CL/IE5: IE5 motors; ATEX cat. 2 on request

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The casing is tubular, made of sheet steel, and the cast aluminium impeller has an adjustable blade angle. Air flows from the motor to the impeller; reverse direction or a fully reversible impeller are available on request. Class H motors are rated for continuous duty S1 and emergency duty S2, and have ball bearings, IP55 protection and one or two speeds. From 0.75 kW the motors meet class IE3, in the 75–200 kW range they are IE4, and THT/IE5 and THT/CL/IE5 (F400 only) have IE5 motors. Supply is 230/400 V 50 Hz up to 3 kW and 400/690 V 50 Hz above 3 kW, with power of 0.55–75 kW per the table. Sizes 40–160 are made for 2, 4, 6 and 8 poles, and two-speed 2/4, 4/8 and 6/12 versions exist. Air temperature in S1 mode is from −25 to +40 °C, and up to +50 °C in a hot climate. The anticorrosion coating is polyester resin cured at 190 °C.

How to choose

THT has a short casing, THT/CL a long casing with an external terminal box and inspection hatch, and the IE5 versions are taken when the motor's energy efficiency class matters. The size is selected by airflow and pressure in the QuickFan program. If the fan has to stand in a soundproof box, look at CJTHT for 158 500 m³/h, for tunnels and metro THT-TM up to 3550 mm in diameter, and for car parks THT/IMP.

Request a price and lead time

THT, THT/CL, THT/IE5 axial smoke extraction fans F400/F300 (400 °C/2 h), up to ~199 000 m³/h. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What fire resistance class do THT fans have?

F400 (400 °C for 2 hours) and F300 (300 °C for 2 hours) per EN 12101-3, certificate 2797 CPR 840443.

Can THT be used for daily ventilation?

Yes, the series is used both for daily ventilation and for emergency removal of smoke and hot gases. The motor is rated for S1 and S2 modes.

What is the maximum airflow of THT/CL?

About 199 000 m³/h for the largest models (THT/CL-160) with a 1600 mm impeller diameter.

What energy efficiency class do THT motors have?

IE3 from 0.75 kW, IE4 for 75–200 kW, IE5 in the THT/IE5 and THT/CL/IE5 versions, which exist only in class F400.

Is there an ATEX version?

ATEX category 2 and a vertical axis are available on request.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.