Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INDUSTRIAL FANS

CMP, CAS medium- and high-pressure centrifugal fans (small series), up to 45 kW

CMP and CAS are small-series direct-drive centrifugal fans, with CMP for medium pressure and CAS for high pressure. Motors go up to 45 kW, and the CMP model line runs from CMP-38 to CMP-2050. They are installed in compact extraction and process systems where pressure is needed at moderate airflow.

Type
small-series single-inlet centrifugal fans: CMP — medium pressure, CAS — high pressure
CMP — impeller
forward-curved blades, galvanized steel; casing — sheet steel (38-2M and 380 — cast aluminum)
CMP — models / power / airflow
CMP-38 … CMP-2050; 1.1…15 kW; up to ~16 500 m³/h (per datasheet)
CMP — air temperature
−25…+120 °C (models 38-2M and 380 — up to +100 °C); up to +250 °C on request

Technical specifications

Typesmall-series single-inlet centrifugal fans: CMP — medium pressure, CAS — high pressure
CMP — impellerforward-curved blades, galvanized steel; casing — sheet steel (38-2M and 380 — cast aluminum)
CMP — models / power / airflowCMP-38 … CMP-2050; 1.1…15 kW; up to ~16 500 m³/h (per datasheet)
CMP — air temperature−25…+120 °C (models 38-2M and 380 — up to +100 °C); up to +250 °C on request
CAS — impellerbackward-curved blades of sheet steel; models 242, 248, 254, 260, 640, 645, 650 — cast aluminum
CAS — range (per CAS/ATEX datasheet)CAS-242 … CAS-1090, 2-pole, 0.37…45 kW, up to ~12 000 m³/h
CAS — air temperature−25…+120 °C; up to +250 °C on request
Motorclass F, IP55
Power supply1~ 230 V (CMP); 3~ 230/400 V (up to 4 kW), 400/690 V (above 4 kW), 50 Hz
Optionsstainless steel, ATEX cat. 2 (CMP/ATEX, CAS/ATEX)
Related seriesCMA, CA — cast aluminum; CAS-S — with silencer; CAM; CMPE; CRL

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The CMP casing is sheet steel, and for models 38-2M and 380 it is unpainted cast aluminum. The impeller is galvanized steel with forward-curved blades. The air must be from −25 to +120 °C, for 38-2M and 380 up to +100 °C, and versions up to +250 °C are made on request. According to the datasheet CMP has a power of 1.1–15 kW and an airflow of up to 16 500 m³/h. In CAS the casing is steel and the impeller blades are backward-curved, while for models 242, 248, 254, 260, 640, 645 and 650 the impeller is cast aluminum. The air temperature is the same, from −25 to +120 °C, and up to +250 °C on request. There is no separate datasheet for CAS, and the range CAS-242 … CAS-1090 with 2-pole motors of 0.37–45 kW and an airflow of up to 12 000 m³/h is taken from the datasheet of the CAS/ATEX version. The motors are class F, IP55, and the coating is polyester, polymerized at 190 °C.

How to choose

First determine the required pressure. For moderate network resistance CMP is taken, and for high resistance one moves to CAS. Single-phase 230 V supply is available only for some CMP models, while three-phase 230/400 V applies up to 4 kW and 400/690 V above 4 kW. For aggressive air stainless steel is made on request, and for explosive atmospheres of category 2 there are CMP/ATEX and CAS/ATEX. Related series are CMA and CA of cast aluminum, CAS-S with a silencer, CAM, CMPE and CRL.

Request a price and lead time

CMP, CAS medium- and high-pressure centrifugal fans (small series), up to 45 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How does CMP differ from CAS?

CMP is designed for medium pressure and has an impeller with forward-curved blades, while CAS is for high pressure with an impeller with backward-curved blades.

What is the maximum air temperature for CMP and CAS?

Standard up to +120 °C, and for CMP models 38-2M and 380 up to +100 °C. Versions for air up to +250 °C are made on request.

What are the power and airflow of the CMP and CAS ranges?

CMP according to the datasheet 1.1–15 kW and up to 16 500 m³/h. The CAS range in the ATEX version covers 2-pole motors of 0.37–45 kW and an airflow of up to 12 000 m³/h.

Are there single-phase fans in this series?

Yes, some CMP models have a 1~ 230 V supply. The rest work from a three-phase 230/400 V 50 Hz supply.

Are these fans made in an explosion-proof version?

Yes, for zones with an explosive atmosphere there are CMP/ATEX and CAS/ATEX with category 2 certification.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.