PF, PF/EC, CJPF high-efficiency Plug Fan centrifugal fans and units based on them

PF is a Plug Fan centrifugal fan, that is, a free impeller without a spiral casing, with sizes from 925 to 2180 and motors of 0.37–18.5 kW. The blades are backward-curved and the drive is direct. The impeller works directly in the chamber of a ventilation unit, air conditioner or air handling unit.

Type
free centrifugal impeller (Plug Fan) with backward-curved blades, direct drive
PF — sizes / power
925…2180; 0.37…18.5 kW (by model codes of the PF / PF/ATEX datasheet)
PF/EC — airflow
up to ~25 700 m³/h (per datasheet); EC IE5 motor with built-in electronics
CJPF — sizes / power / airflow
CJPF-1240 … CJPF-2180; 0.75…4 kW; up to ~21 500 m³/h

Technical specifications

Typefree centrifugal impeller (Plug Fan) with backward-curved blades, direct drive
PF — sizes / power925…2180; 0.37…18.5 kW (by model codes of the PF / PF/ATEX datasheet)
PF/EC — airflowup to ~25 700 m³/h (per datasheet); EC IE5 motor with built-in electronics
CJPF — sizes / power / airflowCJPF-1240 … CJPF-2180; 0.75…4 kW; up to ~21 500 m³/h
PF motorAC IE3; 3~ 230/400 V (up to 4 kW), 400/690 V (above 4 kW)
Air temperature−25…+60 °C
PF constructiongalvanized steel frame, pressure measuring point for automatic control of airflow and pressure; vertical version — except 1871 and 2180
CJPF constructionaluminum profile frame, 25 mm painted sheet panels, removable covers, inlet collector with diffusers, anti-vibration mounts
Optionstwo-speed motors, stainless steel, ATEX (PF/ATEX, CJPF/ATEX)
Frequency controla frequency converter is required for speeds different from the nominal one

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The air is distributed across the cross-section of the unit without a spiral scroll, so such a fan is built into a chamber rather than installed as a separate casing. The frame is galvanized steel, and the pressure measuring port makes it possible to regulate airflow and pressure automatically. The motors are AC IE3, three-phase 230/400 V up to 4 kW and 400/690 V above 4 kW, 50 Hz, and the air temperature is from −25 to +60 °C. All sizes except 1871 and 2180 can be installed vertically. The PF/EC version has an EC IE5 motor with built-in electronics, and its maximum airflow according to the datasheet is about 25 700 m³/h. PFA/EC is more compact and higher-output, also with an IE5 motor, and PF/ATEX is intended for zones 2G/2D. CJPF is a unit in an acoustic casing on an aluminum profile frame, with 25 mm replaceable covers, an inlet collector with diffusers, anti-vibration mounts and standard flanges at the inlet and outlet. The CJPF-1240 … CJPF-2180 range has a power of 0.75–4 kW and an airflow of up to 21 500 m³/h.

How to choose

PF is taken for building into a ready-made unit, and if a separate unit with flanges for ducts is needed, CJPF in a sound-insulated casing. When smooth airflow variation without an external converter is needed, PF/EC is chosen. For operation at speeds different from the nominal one, a PF with an IE3 motor needs a frequency converter. On request, two-speed motors, stainless steel and the PF/ATEX and CJPF/ATEX versions for explosive atmospheres are available.

Request a price and lead time

PF, PF/EC, CJPF high-efficiency Plug Fan centrifugal fans and units based on them. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is a Plug Fan and how does it differ from an ordinary centrifugal fan?

It is an impeller with backward-curved blades without a spiral casing, and it works directly in the chamber of the unit. For this reason PF is installed in ventilation units and air conditioners rather than in a duct.

What is the maximum air temperature for PF?

The air temperature is from −25 to +60 °C.

Can the airflow of PF be regulated automatically?

Yes, there is a pressure measuring port on the frame, and automatic control of airflow and pressure is built on it. For speeds different from the nominal one, a frequency converter is needed.

What is the airflow of the PF/EC and CJPF versions?

According to the datasheet PF/EC gives up to 25 700 m³/h, and the CJPF-1240 … CJPF-2180 range up to 21 500 m³/h.

Can PF be installed vertically?

Yes, the vertical version is available for all sizes except 1871 and 2180.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.