Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INDUSTRIAL FANS

HTMF, THT/ROOF roof axial smoke extraction fans F400/F300, up to ~131 000 m³/h

Roof axial smoke extraction fans HTMF and THT/ROOF for removing smoke and heat from workshops, warehouses, logistics centers and sales halls. Approved to EN 12101-3 in classes F400 (400 °C/2 h) and F300 (300 °C/2 h), certificate 2797 CPR 840443. HTMF gives up to 83 660 m³/h, THT/ROOF up to 131 000 m³/h.

Type
roof axial smoke extraction fans for industrial buildings
Fire resistance
F400 and F300 per EN 12101-3, certificate 2797 CPR 840443
HTMF sizes
56–125 (impeller diameter 560–1250 mm)
HTMF power / airflow
0.55–15 kW; up to ~83 660 m³/h

Technical specifications

Typeroof axial smoke extraction fans for industrial buildings
Fire resistanceF400 and F300 per EN 12101-3, certificate 2797 CPR 840443
HTMF sizes56–125 (impeller diameter 560–1250 mm)
HTMF power / airflow0.55–15 kW; up to ~83 660 m³/h
THT/ROOF sizes40–125 (400–1250 mm)
THT/ROOF power / airflow0.55–37 kW; up to ~131 000 m³/h
Motorclass H, S1/S2, IP55, 1 or 2 speeds
Power supply3~ 230/400 V 50 Hz (up to 3 kW), 400/690 V 50 Hz (above 3 kW)
S1 temperature−25…+40 °C, up to +50 °C
Constructionpainted galvanized steel base, cast aluminium impeller with adjustable blades, guard per UNE-EN ISO 12499
Air outletHTMF: cowl with natural outlet; THT/ROOF: vertical outlet with an aluminium non-return damper
VersionsHTMF/IE5: IE5 motors

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

HTMF has a painted galvanized steel base, an adjustable cast aluminium impeller, a guard per UNE-EN ISO 12499 and a cowl with natural air outlet. Sizes 56–125 (impeller 560–1250 mm) are made for 4, 6 and 8 poles, with two-speed 4/8 and 6/12 versions, power 0.55–15 kW, and HTMF/IE5 is fitted with an IE5 motor. THT/ROOF discharges air vertically, has an aluminium sheet non-return damper against water entering when the fan is stopped, sizes 40–125 and power of 0.55–37 kW. For THT/ROOF, two-speed motors and versions for 2 and 8 poles are made on request. Motors of both series are class H for S1 and S2, IP55, with ball bearings. Supply is 230/400 V 50 Hz up to 3 kW and 400/690 V 50 Hz above 3 kW. Air temperature is from −25 to +40 °C, and up to +50 °C in a hot climate. Both series are also suitable for daily extract ventilation.

How to choose

HTMF is taken when a cowl with natural air outlet and airflow of up to 83 660 m³/h is needed, THT/ROOF where a vertical discharge with a non-return damper and up to 131 000 m³/h is needed. For large airflows without fire resistance requirements there are the related series HTMV and HTMH, and for explosive zones HTMV/ATEX and HTMH/ATEX. If the fan has to stand in a duct, look at THT and THT/CL.

Request a price and lead time

HTMF, THT/ROOF roof axial smoke extraction fans F400/F300, up to ~131 000 m³/h. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How does HTMF differ from THT/ROOF?

HTMF has a cowl with natural air outlet and airflow up to 83 660 m³/h; THT/ROOF discharges air vertically with a non-return damper and gives up to 131 000 m³/h.

What fire resistance class do the roof fans have?

F400 (400 °C/2 h) and F300 (300 °C/2 h) per EN 12101-3, certificate 2797 CPR 840443.

What motor power do HTMF and THT/ROOF have?

HTMF has 0.55–15 kW, THT/ROOF 0.55–37 kW. Motors are class H with IP55 protection.

What is the non-return damper in THT/ROOF for?

The aluminium sheet damper keeps water out of the building when the fan is stopped.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.