Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

INDUSTRIAL FANS

CJTHT, CJTHT/PLUS, CJTHT/ATEX soundproofed axial smoke extraction units F400/F300, up to ~158 000 m³/h

CJTHT axial smoke extraction fan in a sound- and heat-insulated galvanized steel box, approved to EN 12101-3 in classes F400 (400 °C/2 h) and F300 (300 °C/2 h). Sizes 40–125 with a 400–1250 mm impeller deliver up to 158 500 m³/h. The unit is installed in technical rooms and on duct routes of car parks, shopping and public buildings where low noise matters.

Type
axial smoke extraction fan in a soundproofed box, operation in the fire zone
Fire resistance
F400 and F300 per EN 12101-3 (certificates 0370-CPR-0312 F400 and 0370-CPR-0974 F300 per datasheet; 2797 CPR 840443 per website)
Impeller diameter
400–1250 mm (sizes 40–125)
Motor power
0.55–75 kW (per model codes)

Technical specifications

Typeaxial smoke extraction fan in a soundproofed box, operation in the fire zone
Fire resistanceF400 and F300 per EN 12101-3 (certificates 0370-CPR-0312 F400 and 0370-CPR-0974 F300 per datasheet; 2797 CPR 840443 per website)
Impeller diameter400–1250 mm (sizes 40–125)
Motor power0.55–75 kW (per model codes)
Maximum airflowup to ~158 500 m³/h (per datasheet)
Motorclass H, S1/S2 modes, IP55, 1 or 2 speeds, IE3 from 0.75 kW
Power supply3~ 230/400 V 50 Hz (up to 3 kW), 400/690 V 50 Hz (above 3 kW)
Handled air temperature, S1−20 (−25)…+40 °C, up to +50 °C in a hot climate
Box casinggalvanized steel with heat and sound insulation
Number of blades (size 125)6, 9 or 12
VersionsCJTHT; CJTHT/PLUS: with silencers; CJTHT/ATEX: ATEX cat. 3 (Ex II 3G, zone 2)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The box contains a tubular fan with a steel casing and a cast aluminium impeller with an adjustable blade angle. Class H motors work in S1 and S2 modes, have ball bearings, IP55 protection and one or two speeds, and from 0.75 kW meet class IE3. Supply is 230/400 V 50 Hz up to 3 kW and 400/690 V 50 Hz above 3 kW, with power of 0.55–75 kW per model codes. Air temperature in S1 mode is from −20 to +40 °C, and up to +50 °C in a hot climate. Versions for 2, 4, 6 and 8 poles and two-speed 2/4, 4/8 and 6/12 exist, and for size 125 impellers with 6, 9 or 12 blades and 12-pole motors at 500 rpm are available. The fan is coated with polyester resin cured at 190 °C. The sound pressure level at the inlet of small models is 31–71 dB(A) depending on speed. Reverse airflow direction, a fully reversible impeller and a vertical axis are made on request.

How to choose

CJTHT is the basic unit, CJTHT/PLUS also has built-in silencers, and CJTHT/ATEX is certified to ATEX category 3 (Ex II 3G) for zone 2. If noise is not critical and you need an airflow of up to 199 000 m³/h, look at THT and THT/CL without a box. For tunnel shafts there is THT-TM, and for jet ventilation of car parks THT/IMP.

Request a price and lead time

CJTHT, CJTHT/PLUS, CJTHT/ATEX soundproofed axial smoke extraction units F400/F300, up to ~158 000 m³/h. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which fire resistance certificates are given for CJTHT?

The datasheet names 0370-CPR-0312 for F400 and 0370-CPR-0974 for F300, while the website page gives 2797 CPR 840443.

What is the maximum airflow of CJTHT?

Up to 158 500 m³/h per the datasheet table, impeller diameter 400–1250 mm.

Is CJTHT available in an explosion-proof version?

Yes, CJTHT/ATEX has ATEX category 3 (Ex II 3G) certification for zone 2.

What does the CJTHT/PLUS version offer?

It has built-in silencers, so it is quieter than the basic CJTHT. This matters for car parks and public buildings.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.