THT/WALL, THT/WALL-F, THT/WALL/IE5 wall-mounted smoke extraction fans F400/F300 with motorized hatch

The THT/WALL wall-mounted axial fans with a motorized hatch are connected to an extraction duct and used to remove smoke and harmful gases in a fire. They are certified to EN 12101-3 in classes F400 and F300 (certificate 2797 CPR 840443), with sizes 40–125 and motor power of 0.75–37 kW.

Type
wall-mounted axial smoke extraction fan with a motorized hatch, connection to an extraction duct
Fire resistance
400 °C/2 h and 300 °C/2 h, EN 12101-3, certificate 2797 CPR 840443
Sizes
40…125 (per datasheet)
Motor power
0.75…37 kW (by model code)

Technical specifications

Typewall-mounted axial smoke extraction fan with a motorized hatch, connection to an extraction duct
Fire resistance400 °C/2 h and 300 °C/2 h, EN 12101-3, certificate 2797 CPR 840443
Sizes40…125 (per datasheet)
Motor power0.75…37 kW (by model code)
Maximum airflowup to ~131 000 m³/h (per datasheet)
Hatchextruded aluminum with thermal break; heat transfer < 0.89 W/(m²·K); Rw = 27 dB (UNE-EN ISO 10140-2)
Motorclass H, S1/S2, IP55, IE3, 1 or 2 speeds
Impellercast aluminum, adjustable blade pitch
Installationwall mounting flange; versions with top and bottom opening
VersionsTHT/WALL-F — for cold rooms; THT/WALL/IE5 — IE5 motor (F400)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The tubular sheet steel casing has a polyester anti-corrosion coating, the impeller is cast aluminum with adjustable blade pitch, the airflow goes from the motor to the impeller, and the power cable is shielded with EMC protection. The casing support and flange make it possible to fix the fan on a wall. The hatch is made of an extruded aluminum profile with a thermal break, the heat transfer of the assembly is below 0.89 W/(m²·K), and sound insulation is Rw = 27 dB to UNE-EN ISO 10140-2. The construction is watertight, with open/closed position indicators, versions with top and bottom opening, and manual opening. The class H motors are rated for duties S1 and S2, have ball bearings, IP55 protection, IE3 class and one or two speeds, with 2-pole, 4-pole and 6-pole versions. The airflow in the table reaches about 131 000 m³/h. In daily mode the fan works for general ventilation.

How to choose

THT/WALL-F is intended for smoke extraction from cold rooms, where the thermal insulation of the enclosure and the absence of cold losses matter. THT/WALL/IE5 has an IE5 motor and 400 °C/2 h certification. For systems without smoke extraction requirements there are the WALL/AXIAL, WALL/FREE and WALL/DUCT series. Starting is done from the fire alarm system, which is not included in the delivery set.

Request a price and lead time

THT/WALL, THT/WALL-F, THT/WALL/IE5 wall-mounted smoke extraction fans F400/F300 with motorized hatch. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What fire resistance classes does THT/WALL have?

F400 and F300 to EN 12101-3, certificate 2797 CPR 840443.

Is there a version for cold rooms?

Yes, THT/WALL-F. It is designed for smoke extraction from rooms where thermal insulation and the absence of cold losses matter.

What are the thermal and sound insulation of the hatch?

Heat transfer is below 0.89 W/(m²·K), and sound insulation is Rw = 27 dB to UNE-EN ISO 10140-2.

Is the fire control system included in the delivery set?

No. Starting is done from the fire alarm system, which is not included in the delivery set.

What is the range of power and sizes?

Sizes 40–125, motor power 0.75–37 kW, with 2-pole, 4-pole and 6-pole versions.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.