Smart-UPS Battery Systems — external battery units for UPS
Country: France · Model: Smart-UPS Battery Systems
External battery units for Smart-UPS series UPS. They extend the runtime when the standard UPS battery is not enough to ride through a long mains outage. The units are placed next to the UPS in a server rack or in a separate room.
- Purpose
- extending the runtime of Smart-UPS units
Technical specifications
| Purpose | extending the runtime of Smart-UPS units |
|---|
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The additional battery unit is connected to the UPS as an external battery. The load that the UPS holds from the mains is shared between the internal and external batteries, so the runtime depends on the capacity of the whole assembly and on the consumption of the connected equipment. For servers, network nodes and security systems, this is a way to move from minutes to a longer backup without replacing the UPS itself. The unit works together with the Smart-UPS, so the inverter, the charger and the control stay in the UPS, and the external unit only adds an energy reserve. The detailed capacity, voltage and number of cells depend on the particular unit, and they are taken from the datasheet of the UPS the unit is selected for. The charging current is agreed in the same way, so that the extended battery charges in an acceptable time.
How to choose
First find out which Smart-UPS model the unit is selected for, because compatibility is set by the UPS. Then calculate the required runtime for the real load. For three-phase Galaxy UPS there are separate lithium-ion battery systems with 10, 13, 16 or 17 modules, with a nominal voltage of 304, 395, 486 or 517 V DC and a weight of 355–490 kg. Smart-UPS Battery Systems units are not connected to these systems.
Request a price and lead time
Smart-UPS Battery Systems — external battery units for UPS. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What are external Smart-UPS battery units for?
They extend the runtime of a Smart-UPS. The inverter and the control stay in the UPS itself.
What does the runtime of a UPS with an external battery unit depend on?
On the total capacity of the internal and external batteries and on the power of the connected load. The lower the load, the longer the backup.
Can such a unit be connected to a three-phase Galaxy UPS?
No, Galaxy uses separate lithium-ion systems with 10, 13, 16 or 17 modules.
Where do you find the voltage and capacity of the external unit?
In the technical description of the UPS and of the unit itself, because the parameters depend on the model. They are agreed with the UPS before the order.