grid | power V H bloc (OGi bloc) low-maintenance 4, 6 and 12 V blocks

Low-maintenance 4, 6 and 12 V blocks of approx. 60–260 Ah on OGi grid plates. They are used in UPS, switchgear, emergency lighting, for starting diesel generators and in railway infrastructure.

Technology
lead-acid, OGi grid plates, pocket separators
Design
4 V, 6 V and 12 V blocks, approx. 60–260 Ah
Application
UPS, diesel generator starting, railway infrastructure
Standards
DIN EN 60896, DIN 40738

Technical specifications

Technologylead-acid, OGi grid plates, pocket separators
Design4 V, 6 V and 12 V blocks, approx. 60–260 Ah
ApplicationUPS, diesel generator starting, railway infrastructure
StandardsDIN EN 60896, DIN 40738

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The block format reduces the number of inter-cell connections compared with a battery of individual 2 V cells, installation is faster and there are fewer control points. OGi grid plates deliver high current, so the blocks confidently crank the diesel generator starter and hold the UPS load in the first minutes. Pocket separators keep the active mass near the plate and protect against short circuits caused by its shedding, which extends the service life under frequent starts. The transparent case shows the electrolyte level without opening the block. The battery is flooded, water needs to be added rarely, but room ventilation is mandatory. The design meets DIN EN 60896 and DIN 40738.

How to choose

The block voltage of 4, 6 or 12 V is chosen so that the string gives the required voltage with a minimum of connections, and the capacity within 60–260 Ah is determined by the starting current or autonomy time. If maintenance is not possible at all, take sealed AGM blocks grid | power VR X at 57–166 Ah. For warm rooms up to +55 °C, AGM grid | Xtreme VR is suitable.

Request a price and lead time

grid | power V H bloc (OGi bloc) low-maintenance 4, 6 and 12 V blocks. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What voltages do grid | power V H bloc blocks have?

The blocks are made for 4, 6 and 12 V with a capacity of approx. 60–260 Ah.

Are OGi bloc blocks suitable for starting a diesel generator?

Yes, starting diesel generators is directly part of the intended use of the series. OGi plates are designed for high starting currents, and the block capacity is up to 260 Ah.

Does OGi bloc require maintenance?

The blocks are low-maintenance but flooded, so the electrolyte level is checked periodically and water is added. The design meets DIN EN 60896 and DIN 40738.

Where else are grid | power V H bloc blocks used?

In UPS, switchgear, emergency lighting and railway infrastructure. The 12 V blocks are convenient where a minimum of connections is needed.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.