grid | power V L low-maintenance OPzS cells

Flooded low-maintenance OPzS 2 V cells of up to 3500 Ah and 6 and 12 V blocks with tubular plates. They are designed for long discharge from 1 to over 10 hours in power engineering, at substations, in telecommunications and emergency lighting.

Technology
flooded lead-acid with liquid electrolyte, tubular plates
Design
2 V cells (up to 3500 Ah), OPzS blocks of 6 and 12 V
Options
AquaGen recombination plugs
Standards
DIN 40736-1, IEC 60896-11

Technical specifications

Technologyflooded lead-acid with liquid electrolyte, tubular plates
Design2 V cells (up to 3500 Ah), OPzS blocks of 6 and 12 V
OptionsAquaGen recombination plugs
StandardsDIN 40736-1, IEC 60896-11

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Liquid electrolyte and tubular positive plates give the durability of a stationary battery that stands for years in float mode on a DC switchboard. The flooded design requires a ventilated room and periodic topping up with distilled water, but the condition of each cell can be seen from the electrolyte level and density. Optional AquaGen recombination plugs return part of the gas to water, so topping up is needed less often and less hydrogen is released. A capacity of up to 3500 Ah in a single 2 V cell covers the load of large substations and power plants without parallel strings. The cells are made to DIN 40736-1, and the tests meet IEC 60896-11.

How to choose

The discharge duration from 1 to over 10 hours and the required capacity determine the cell size. For small automation batteries, OPzS blocks of 6 and 12 V are more convenient. AquaGen plugs are worth ordering together with the cells if staff are rarely present on site. When there is no separate battery room, switch to sealed series, for example AGM grid | power VR M with 2 V cells up to 1000 Ah.

Request a price and lead time

grid | power V L low-maintenance OPzS cells. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the maximum capacity of grid | power V L OPzS cells?

The 2 V cells are made with a capacity of up to 3500 Ah. For smaller batteries there are OPzS blocks of 6 and 12 V.

What discharge time are OPzS V L cells designed for?

For long discharge from 1 to over 10 hours. For discharges lasting minutes, thin-plate series are a better fit.

What are AquaGen plugs for?

AquaGen recombination plugs return gases as water, so the topping-up interval grows and less hydrogen is released. The option is available for 2 V cells and for 6 and 12 V blocks.

Which standards do OPzS V L cells meet?

The cells are made to DIN 40736-1 and meet IEC 60896-11 for flooded lead-acid batteries.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.