LPF — front-terminal AGM batteries for telecom, 40–200 Ah
Country: China · Model: LPF
Front-terminal 12 V AGM monoblocks of 40–200 Ah (C10) with a design service life of 12 years. They are mounted in 19″ and 23″ telecom cabinets at base stations and communication nodes.
- Technology
- AGM VRLA
- Voltage
- 12 V
- Capacity
- 40–200 Ah (C10)
- Service life
- 12 years
Technical specifications
| Technology | AGM VRLA |
|---|---|
| Voltage | 12 V |
| Capacity | 40–200 Ah (C10) |
| Service life | 12 years |
| Terminals | front, 19″/23″ cabinets |
| Case | ABS UL94-HB (UL94-V0 optional) |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Both poles are brought out to the front panel, and the battery is serviced from the front of the cabinet, with no access needed from the back or top. The narrow elongated case is designed for the rack width, so several blocks stand side by side on a shelf. The capacity is rated in the C10 mode, which corresponds to typical backup of a telecom load. AGM VRLA technology holds the electrolyte in a glass separator; the monoblock is sealed and needs no topping up. The case is made of ABS of class UL94-HB; a UL94-V0 version is available on request for sites with stricter fire safety requirements.
How to choose
Select the capacity for the rack load and the required backup time; in the range from 40 to 200 Ah the terminals and cabinet fit are the same. If the site has no air conditioner, consider LHT. For long float operation with rare discharges there are gel LPFG batteries, and for daily cycling lithium LFeLi with a life of 5000 cycles.
Request a price and lead time
LPF — front-terminal AGM batteries for telecom, 40–200 Ah. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What capacity do LPF batteries have?
From 40 to 200 Ah at C10 discharge; the nominal voltage of each monoblock is 12 V.
Which cabinets do LPF front-terminal batteries fit?
The series is designed for 19″ and 23″ telecom cabinets; the terminals are accessible from the front without removing the shelf.
How long does a front-terminal LPF AGM battery last?
The design service life is 12 years in float mode. At a higher temperature in the cabinet the actual life is shorter.
Are LPF batteries available in a non-flammable case?
The base case is ABS UL94-HB, and for sites with strict fire safety requirements a UL94-V0 option is available.
What does the C10 mark in the LPF battery capacity mean?
The capacity of 40–200 Ah is measured at a ten-hour discharge. With a shorter discharge at a large current the available capacity will be lower, so for a UPS with short autonomy the calculation is made from the power tables.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.