Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LIFEPO4 LITHIUM BATTERIES

SOLAR gel VRLA 12 V batteries for solar systems 27–230 Ah

SOLAR are maintenance-free 12 V gel blocks for small off-grid solar systems, country houses and signalling equipment. Capacity is 27–230 Ah (C100), service life 800 cycles at 60 % DoD.

Technology
VRLA, gel, flat plates
Voltage
12 V
Capacity
27–230 Ah (C100)
Cycle life
800 cycles at 60 % DoD (C10)

Technical specifications

TechnologyVRLA, gel, flat plates
Voltage12 V
Capacity27–230 Ah (C100)
Cycle life800 cycles at 60 % DoD (C10)
StandardsIEC 61427, IEC 60896-21/22; UL
ModelsS12/27 G5 … S12/230 A

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

This is a 12 V block with gel electrolyte and flat plates that needs no topping up. The model range starts with the S12/27 G5 and ends with the S12/230 A. The capacity is given for the hundred-hour discharge C100, so the real output at higher currents is calculated separately. The cycle life is 800 cycles at 60 % depth of discharge at C10, which is enough for seasonal use or alarm systems where discharges are shallow. The series is tested to IEC 61427 and IEC 60896-21/22 and has UL approval.

How to choose

Compare the required capacity with the 27–230 Ah range and the number of cycles with the 800 cycle life. When there are many discharges or the bank must be larger, look at the SOLAR BLOCK with a cycle life of 1200 cycles at 60–330 Ah. For large systems built from 2 V cells with a capacity of 285–3821 Ah the A600 SOLAR is intended. If a gel battery is needed for standby float use, consider the A500 of 12 V and 25–200 Ah.

Request a price and lead time

SOLAR gel VRLA 12 V batteries for solar systems 27–230 Ah. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What systems are 12 V SOLAR blocks intended for?

Small off-grid solar systems, country houses and signalling equipment.

What cycle life do SOLAR blocks have?

800 cycles at 60 % depth of discharge at C10.

At what current is the SOLAR capacity given?

At C100, range 27–230 Ah. With faster discharge the delivered capacity is lower.

Does water need to be added to the SOLAR?

No, the VRLA gel block needs no maintenance.

Which option to choose if more cycles are needed?

SOLAR BLOCK gives 1200 cycles at 60 % DoD, and A600 SOLAR from 2400 cycles.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.