XPL high-rate 12 V batteries for data center UPS (top terminals)
Country: Taiwan · Model: XPL
XPL 12 V monoblocks with top terminals deliver 200–650 W per cell over a 15-minute discharge to 1.67 V/cell. This senior data center UPS series is aimed at the markets of the Americas and the Asia-Pacific region.
- Voltage
- 12 V
- Power
- 200–650 W/cell (15 min to 1.67 V/cell)
- Technology
- lead-acid VRLA-AGM, maintenance-free, pure lead, thin plates
- Service life
- up to 10 years in standby mode at 25 °C
Technical specifications
| Voltage | 12 V |
|---|---|
| Power | 200–650 W/cell (15 min to 1.67 V/cell) |
| Technology | lead-acid VRLA-AGM, maintenance-free, pure lead, thin plates |
| Service life | up to 10 years in standby mode at 25 °C |
| Standards | IEC 60896-21/22, UL 1973 (MH66728), UL 1989 (MH14533) |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The power range covers UPS from server rooms to large machine halls. Thin pure lead plates deliver high current and degrade little on constant float charge, so the service life is up to 10 years in standby mode at 25 °C. The top terminal position is customary for racks and battery cabinets where monoblocks stand on shelves with access from above. The VRLA-AGM design is sealed and water is not refilled. Compliance with IEC 60896-21/22 and UL 1973 (MH66728) and UL 1989 (MH14533) certificates are convenient for projects carried out to American standards.
How to choose
The required power per cell is calculated from the UPS load and the number of cells in a string, after which the model is selected from the range of 200–650 W/cell. If the rack requires servicing from the front or the discharge is sized for seconds, XPL-FT suits better. For small household UPS, GP monoblocks of 12 V are enough.
Request a price and lead time
XPL high-rate 12 V batteries for data center UPS (top terminals). We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What power does the XPL battery deliver?
From 200 to 650 W per cell over a 15-minute discharge to 1.67 V/cell.
How long does an XPL battery last in a UPS?
Up to 10 years in standby mode at 25 °C; a higher temperature in the room shortens the life.
How does XPL differ from XPL-FT?
XPL has top terminals and is designed for a 15-minute discharge, while XPL-FT has front terminals and works on a short discharge from 30 seconds.
Which markets is the XPL series intended for?
For the markets of the Americas and the Asia-Pacific region; the series complies with IEC 60896-21/22 and holds UL 1973 and UL 1989 certificates.