NPH / NPW — high-rate VRLA AGM batteries 12 V, 5–16 Ah
Country: Japan · Model: NPH / NPW
Compact NPH and NPW batteries at 12 V with a capacity of 5–16 Ah have a high-rate design and are intended for low-power UPS systems. The typical installation place is the battery compartment of an office or server UPS.
- Technology
- VRLA AGM, high rate
- Nominal voltage
- 12 V
- Capacity (20 h)
- 5–16 Ah
- Mode
- standby
Technical specifications
| Technology | VRLA AGM, high rate |
|---|---|
| Nominal voltage | 12 V |
| Capacity (20 h) | 5–16 Ah |
| Mode | standby |
| EUROBAT classification | Standard commercial, 3–5 years |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The high-rate design is made for a discharge within a few minutes, when the UPS powers the load until servers are shut down correctly or a backup source starts. So in the technical data, look at the discharge power for a short time rather than at the capacity at a 20-hour discharge. The operating mode is standby, and the battery is constantly kept on float charge by the UPS. The EUROBAT class Standard commercial corresponds to a service life of 3–5 years, so battery replacement in small UPS systems is included in the maintenance schedule. The case is sealed, and maintenance comes down to checking the voltage and a visual inspection.
How to choose
Select the capacity by how many minutes the UPS must hold the load and by the size of the standard compartment. If you need a universal battery that also works in cyclic mode, NP at 6 or 12 V with a capacity of 1–65 Ah will do. For large UPS systems with a longer service life, EN at 86.4–579 Ah of the Very long life class is more suitable.
Request a price and lead time
NPH / NPW — high-rate VRLA AGM batteries 12 V, 5–16 Ah. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which UPS systems are NPH and NPW batteries suitable for?
For low-power UPS systems with a 12 V battery that need a short discharge at high current. The capacity of the models is 5–16 Ah.
What is the service life of NPW in a UPS?
The series has the EUROBAT class Standard commercial, i.e. 3–5 years in standby mode.
How does a high-rate battery differ from a regular one?
It is designed to deliver more current in a short discharge, so within a few minutes the UPS gets more power from the same size.
Can NPW be installed instead of a regular NP in a UPS?
Yes, if the 12 V voltage, capacity, dimensions and terminal type match. The high-rate version handles the short discharge typical of UPS systems better.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.