Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LIFEPO4 LITHIUM BATTERIES

Calor XHT-FT high-temperature 12 V batteries for data center UPS

Calor XHT-FT is designed to work in warm battery rooms; a 12 V monoblock delivers up to 2000 W per cell, and a 480 V DC string up to 500 kW. The battery discharges at maximum power in 30 seconds and helps reduce data center cooling costs.

Voltage
12 V
Power
up to 2000 W/cell; up to 500 kW per 480 V DC string
Models
XHT7000FT, XHT7700FT, XHT8000FT, XHT9000FT
Technology
lead-acid VRLA-AGM, maintenance-free, pure lead, in-case formation (ICF)

Technical specifications

Voltage12 V
Powerup to 2000 W/cell; up to 500 kW per 480 V DC string
ModelsXHT7000FT, XHT7700FT, XHT8000FT, XHT9000FT
Technologylead-acid VRLA-AGM, maintenance-free, pure lead, in-case formation (ICF)
Service life12+ years at 25 °C, up to 10 years at 35 °C
Caseflame-retardant polymer UL 94-V0
StandardsIEC 60896-21/22, UL 1973 (MH66728), UL 1989 (MH14533)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The main feature of the series is temperature. At 35 °C the service life reaches 10 years, and at 25 °C it exceeds 12 years, so the battery room can be kept warmer, saving on air conditioning. Pure lead plates are formed in the case itself (ICF), which reduces the spread of parameters between monoblocks in a string. The case is made of flame-retardant polymer of class UL 94-V0. The range consists of four models, XHT7000FT, XHT7700FT, XHT8000FT and XHT9000FT, all with front terminals for servicing from the front. Compliance with IEC 60896-21/22 and UL 1973 (MH66728) and UL 1989 (MH14533) certificates.

How to choose

The model is determined by the required string power, up to 500 kW per 480 V DC branch, and the calculated discharge time. If the battery room is cooled to 25 °C and temperature resistance is not needed, you can consider the manufacturer's other front-terminal series for data centers. For small loads this battery is excessive; GP of 12 V is more suitable there.

Request a price and lead time

Calor XHT-FT high-temperature 12 V batteries for data center UPS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How long does Calor XHT-FT last at 35 °C?

Up to 10 years at 35 °C and more than 12 years at 25 °C.

What power does a Calor XHT-FT string deliver?

Up to 500 kW per 480 V DC string; one monoblock delivers up to 2000 W per cell.

Which models are in the Calor XHT-FT series?

Four 12 V models, XHT7000FT, XHT7700FT, XHT8000FT and XHT9000FT.

What does in-case formation ICF mean?

The plates are formed inside the assembled case, which reduces the spread of parameters between monoblocks of a 480 V DC string.

Is the Calor XHT-FT battery case flame-retardant?

Yes, the case is made of flame-retardant polymer of class UL 94-V0.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.