HS160-PA — high-voltage LFP battery for commercial storage, 64–256 kWh

The 16.0 kWh HS160-PA module is stacked from 4–16 units, which gives 64–256 kWh at 204.8–819.2 V. The battery is installed in commercial energy storage systems together with the X3-TRENE 125K PCS.

Module
HS160-PA, 16.0 kWh, LFP, 495 × 228 × 800 mm, 117.5 kg
System
4–16 modules: 64–256 kWh (usable 60.8–243.2 kWh at 95% DoD)
Voltage
204.8–819.2 V
Charge/discharge power
32–128 kW (0.5C), current 157 A (max. 173 A)

Technical specifications

ModuleHS160-PA, 16.0 kWh, LFP, 495 × 228 × 800 mm, 117.5 kg
System4–16 modules: 64–256 kWh (usable 60.8–243.2 kWh at 95% DoD)
Voltage204.8–819.2 V
Charge/discharge power32–128 kW (0.5C), current 157 A (max. 173 A)
Cycle life> 8000 cycles
Coolingair, IP20, for indoor use
StandardsIEC 62619, IEC 62477, IEC 63056, IEC 61000, UL 9540A, UN38.3
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Usable capacity at 95% depth of discharge is 60.8–243.2 kWh, and charge and discharge power at 0.5C is 32–128 kW. The rated current is 157 A and the maximum is 173 A, so DC cables and protection are sized for exactly these values. Up to 64 modules are connected in parallel on the DC side, and for large sites capacity is built from several stacks. Each module measures 495 × 228 × 800 mm and weighs 117.5 kg, so the stack is assembled on a level floor after checking the floor loading. Cooling is by air and the protection rating is IP20, so the battery is installed only in a ventilated room. The cycle life exceeds 8000 cycles. Compliance is stated with the IEC 62619, IEC 62477, IEC 63056, IEC 61000, UL 9540A and UN38.3 standards, which simplifies approval by the fire service and the insurer.

How to choose

The number of modules in a stack determines both energy and voltage, so it is chosen to match the DC input range of the PCS. Four modules give the minimum 64 kWh, and sixteen give 256 kWh and 128 kW. For a house this battery is too large; there HS units of 5.1–92 kWh or low-voltage LD units of 5.1–32.1 kWh are taken.

Request a price and lead time

HS160-PA — high-voltage LFP battery for commercial storage, 64–256 kWh. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many HS160-PA modules can be connected into one system?

A stack has from 4 to 16 modules, that is, 64–256 kWh, and up to 64 modules are connected in parallel on the DC side.

What is the usable capacity of the HS160-PA at 95% DoD?

From 60.8 to 243.2 kWh depending on the number of modules in the stack.

Can the HS160-PA be installed outdoors?

No, the battery has IP20 and air cooling, and it is intended for indoor use only.

Which standards does the HS160-PA comply with?

IEC 62619, IEC 62477, IEC 63056, IEC 61000, UL 9540A and UN38.3 are stated.

What is the discharge current of the HS160-PA?

The rated current is 157 A, the maximum is 173 A, and the power at 0.5C is 32–128 kW.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.