EnergyCore Li5 / Li7 — lithium-ion battery cabinets for UPS

Lithium-ion UPS battery cabinet with its own BMS, holding 17.3–31.1 kWh in the Li5 version with up to 263 kW of discharge power. It works with data center and AI-load UPS and takes less floor space than a VRLA bank.

Li5 energy
17.3 / 27.6 / 31.1 kWh (10 / 16 / 18 modules)
Li5 voltage
288 / 461 / 518 V DC
Li5 max. discharge power
146 / 234 / 263 kW
Chemistry
LFP (Li5), NMC/LMO (Li7)

Technical specifications

Li5 energy17.3 / 27.6 / 31.1 kWh (10 / 16 / 18 modules)
Li5 voltage288 / 461 / 518 V DC
Li5 max. discharge power146 / 234 / 263 kW
ChemistryLFP (Li5), NMC/LMO (Li7)
Discharge time5 min (Li5), 7 min (Li7)
Dimensions600 × 750 × 2000 mm
Service life10–15 years
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

A Li5 cabinet holds 10, 16 or 18 modules for 17.3, 27.6 or 31.1 kWh at 288, 461 or 518 V DC. Maximum discharge power is 146, 234 and 263 kW respectively, so the module count follows the UPS DC bus voltage and the power to be carried. Li5 uses LFP chemistry with a 5 min discharge, Li7 uses NMC/LMO with a 7 min discharge. The 600 × 750 × 2000 mm enclosure lines up with the UPS cabinets in one row. The BMS watches every module and reports to the UPS, replacing the manual string checks of lead-acid. Battery service life is 10–15 years, so fewer battery replacements fall within the life of the UPS.

How to choose

Match the cabinet voltage to the UPS DC bus first, then check that discharge power covers the load for the chosen time. Li5 on LFP is taken where thermal stability comes first, Li7 on NMC/LMO gives the longer discharge. For a EXM2 at 100–250 kVA the cabinet count follows the required runtime, and the same logic applies to larger units such as EXL S1 at 300–1250 kW. Cabinet size stays the same, so the row layout does not depend on the module count inside.

Request a price and lead time

EnergyCore Li5 / Li7 — lithium-ion battery cabinets for UPS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the capacity of an EnergyCore Li5 cabinet?

17.3, 27.6 or 31.1 kWh depending on the module count.

What chemistry do EnergyCore Li5 and Li7 use?

Li5 is LFP with a 5 min discharge, Li7 is NMC/LMO with a 7 min discharge.

What are the dimensions of the EnergyCore battery cabinet?

600 × 750 × 2000 mm, with a service life of 10–15 years.

What DC voltage does an EnergyCore Li5 cabinet output?

288, 461 or 518 V DC for 10, 16 or 18 modules, with discharge power of 146, 234 or 263 kW.

Which UPS work with EnergyCore lithium cabinets?

The cabinets serve data center UPS, and EXM2 at 100–250 kVA, for example, is listed as compatible with EnergyCore Li-ion.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.