Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LIFEPO4 LITHIUM BATTERIES

Lithium Battery Solutions — lithium-ion battery systems for UPS and ESS

Packaged lithium-ion battery systems for units and Solartech energy storage systems are built on RS BATLIO 5300T modules with LFP (LiFePO4) chemistry and 5.3 kWh capacity. The batteries handle a high cycle count, offer high energy density and real-time monitoring. They replace lead-acid battery cabinets on three-phase UPS units and serve in BESS at solar plants.

Composition
battery modules with built-in electronics, battery circuit breaker, BMS unit, power and communication cables
The manufacturer module
RS BATLIO 5300T, LFP (LiFePO4), 5.3 kWh, BMS HV-RS BOX
Compatible BMS
, Cegasa, Vision,, Ampace, HV-RS BOX
EnergyManager 2 gateway
UPS-to-BMS communication, peak shaving (up to 4 energy meters), Modbus/TCP, RS485, Ethernet IPv4/IPv6

Technical specifications

Compositionbattery modules with built-in electronics, battery circuit breaker, BMS unit, power and communication cables
The manufacturer moduleRS BATLIO 5300T, LFP (LiFePO4), 5.3 kWh, BMS HV-RS BOX
Compatible BMS, Cegasa, Vision,, Ampace, HV-RS BOX
EnergyManager 2 gatewayUPS-to-BMS communication, peak shaving (up to 4 energy meters), Modbus/TCP, RS485, Ethernet IPv4/IPv6
Compatible UPSNextEnergy NXE, Master HP, Master HE, Master MPS and others
Applicationsdata centers, telecom, healthcare, transport, manufacturing, energy storage from PV, wind and cogeneration, smart grid and off-grid
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The kit includes battery modules with built-in electronics, a battery breaker, the BMS HV-RS BOX unit, and power and communication cables, so the system is assembled on site without sourcing third-party parts. Besides the in-house unit, BMS from the manufacturer, Cegasa, Vision, and Ampace are supported. The BMS watches the modules in real time and reports their status to the UPS. The EnergyManager 2 board links the UPS with the BMS and performs peak shaving, limiting the power the UPS draws from the grid, with up to 4 energy meters connected. The gateway works over Modbus/TCP, RS485 and Ethernet IPv4/IPv6. The batteries connect to NextEnergy NXE, Master HP, Master HE, Master MPS and other UPS in the range. Applications span data centers, telecom, healthcare, transport, manufacturing, energy storage from solar, wind and cogeneration, smart grid and off-grid.

How to choose

Count modules from the required energy, dividing it by the 5.3 kWh of one RS BATLIO 5300T with the allowed depth of discharge in mind. Batteries with BMS from the compatible brands also connect to units when a project is tied to a given supplier. Add EnergyManager 2 when the UPS has to shave consumption peaks and not just hold a reserve. Where a few seconds of autonomy will do, lithium is unnecessary and the SuperCaps UPS at 1–800 kVA is simpler.

Request a price and lead time

Lithium Battery Solutions — lithium-ion battery systems for UPS and ESS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the capacity of the RS BATLIO 5300T lithium module?

5.3 kWh, LFP (LiFePO4) chemistry, managed by the BMS HV-RS BOX.

What does the EnergyManager 2 board do?

It passes data between the UPS and the BMS and performs peak shaving with up to 4 energy meters connected.

Which BMS are the lithium UPS batteries compatible with?

, Cegasa, Vision,, Ampace and the in-house HV-RS BOX.

Which models accept the lithium batteries?

NextEnergy NXE, Master HP, Master HE, Master MPS and other UPS in the range. The BMS link runs through EnergyManager 2 over Modbus/TCP or RS485.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.