OPzS stationary flooded batteries 64–3671 Ah

OPzS stationary flooded batteries with tubular plates have a capacity of 64–3671 Ah and a service life of up to 20 years. These vented lead-acid batteries are installed for standby power of infrastructure, for example on DC buses and in UPS systems.

Technology
flooded (vented) lead-acid, tubular plates
Capacity
64–3671 Ah
Design
2 V cells, 6 and 12 V monoblocs
Service life
up to 20 years

Technical specifications

Technologyflooded (vented) lead-acid, tubular plates
Capacity64–3671 Ah
Design2 V cells, 6 and 12 V monoblocs
Service lifeup to 20 years
Operating temperature–20…+55 °C
Lead purity99.99%

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The liquid electrolyte and vented design need water to be added periodically, but water consumption in this series is reduced, so the intervals between servicing are longer. To order, the cells are fitted with flame-arresting vent plugs, which do not let a flame into the battery from a nearby spark. Lead purity is 99.99%, which reduces self-discharge and gas evolution. The tubular plates hold the active mass in gauntlets and, together with the reserve of liquid electrolyte, give a long service life in float mode. The operating temperature range of –20…+55 °C removes the requirement to heat the battery room, although in winter the capacity will be lower. The range consists of 2 V cells and 6 and 12 V monoblocs. The battery room is equipped with ventilation to remove the hydrogen released during charging.

How to choose

Selection of OPzS starts with the capacity for the required autonomy time and the bus voltage, which is built by connecting 2 V cells or 6 and 12 V monoblocs in series. If the room has no ventilation or maintenance staff, it is better to take the sealed gel OPzV of 54–3718 Ah. For solar power plants with daily cycling the related RES OPzS series of 89–4923 Ah with a life of 2800 cycles at 50% DoD is suitable. Flame-arresting vent plugs are ordered at once if increased fire safety requirements are placed on the battery room.

Request a price and lead time

OPzS stationary flooded batteries 64–3671 Ah. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How often should water be added to OPzS batteries?

The interval depends on the float mode and temperature, but in this series water consumption is reduced. The electrolyte level is checked during scheduled maintenance and distilled water is added.

Why are flame-arresting vent plugs used in flooded batteries?

They prevent a flame from an external spark from getting inside the cell, where there is hydrogen. For OPzS such plugs are supplied as an option.

What is the service life of OPzS stationary batteries?

Up to 20 years is declared. This life is reached with the correct float voltage, timely water topping up and a moderate temperature in the battery room.

How does OPzS differ from RES OPzS?

Both series are flooded with tubular plates, but the OPzS is designed for standby power with rare discharges. The RES OPzS is intended for daily cycling in systems on renewable sources and has a life of 2800 cycles at 50% DoD.

In what range of capacities are OPzS batteries made?

The range covers 64–3671 Ah in 2 V cells and 6 and 12 V monoblocs.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.