Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LIFEPO4 LITHIUM BATTERIES

RES OPzS flooded batteries for renewables 89–4923 Ah

RES OPzS flooded batteries of 89 to 4923 Ah, which withstand 2800 cycles at 50% DoD, are intended for off-grid and hybrid solar power plants. They work as a lead-acid system for storing energy from renewable sources where the battery is discharged and charged every day.

Technology
flooded lead-acid, tubular plates
Capacity
89–4923 Ah
Design
2 V cells, 6 and 12 V monoblocs
Cycle life
2800 cycles at 50% DoD, 20 °C

Technical specifications

Technologyflooded lead-acid, tubular plates
Capacity89–4923 Ah
Design2 V cells, 6 and 12 V monoblocs
Cycle life2800 cycles at 50% DoD, 20 °C
Operating temperature–20…+55 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The design is vented, the electrolyte is liquid and the gases are released through the vent plugs, so the battery is placed in a ventilated room and distilled water is added periodically. Tubular plates tolerate deep cycles better than flat ones, and they give the declared life at a temperature of 20 °C. The operating temperature lies between –20 and +55 °C, but in the cold the available capacity falls, and in the heat the life is shortened. The range consists of 2 V cells and 6 and 12 V monoblocs. 12 V monoblocs are convenient for building a small battery for a private plant, and large 2 V cells suit hybrid systems at commercial and remote sites. The liquid electrolyte makes it possible to check the acid density and to restore the battery with an equalising charge after deep discharges.

How to choose

Capacity is calculated from the daily consumption and the permissible depth of discharge, because at 50% DoD the battery delivers its full declared life. The system voltage is built by connecting 2 V cells or 6 and 12 V monoblocs in series for the input of a hybrid inverter. If the battery mostly stays in standby rather than being cycled, the gel OPzV of 54–3718 Ah with a service life of up to 20 years is better suited. For 12 V mobile systems with deeper discharges there are the TRIFORCE Lithium 12V LiFePO4 monoblocs with a life of up to 3000 cycles at 80% DoD.

Request a price and lead time

RES OPzS flooded batteries for renewables 89–4923 Ah. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many cycles does the RES OPzS battery withstand?

The declared cycle life is 2800 cycles at a depth of discharge of 50% and a temperature of 20 °C. Deeper discharges and higher temperature reduce this figure.

Can the RES OPzS be installed in an unheated room?

The operating range is from –20 to +55 °C, so the battery works without heating too. In winter a capacity reserve is allowed for, because in the cold the output is lower.

Does water have to be added to RES OPzS flooded batteries?

Yes, these are vented batteries with liquid electrolyte, so the level is checked and distilled water is added. The room must be ventilated, because hydrogen is released during charging.

Which voltages does the RES OPzS range of 89–4923 Ah have?

There are 2 V cells and 6 and 12 V monoblocs. The largest capacities are more convenient to build from 2 V cells, from which a battery for the voltage of a hybrid inverter is assembled.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.