DataSafe XE — 12 V TPPL batteries for sub-5-minute discharge in data centers

DataSafe XE 12 V TPPL batteries are optimized for short high-rate discharges under 5 minutes and deliver 764–1,150 W per cell over 15 minutes. They go into UPS systems of hyperscale and newly built data centers.

Technology
TPPL, VRLA
Voltage
12 V
Capacity
205–1,040 Ah (8 h)
Power
764–1,150 W/cell (15 min to 1.67 V/cell)

Technical specifications

TechnologyTPPL, VRLA
Voltage12 V
Capacity205–1,040 Ah (8 h)
Power764–1,150 W/cell (15 min to 1.67 V/cell)
ApplicationUPS for hyperscale data centers
Customs codes (for reference)
HS code8507.20
UKTZED code (Ukraine)8507208090
CN code (EU)85072080

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

New data centers often need the battery only until the diesel generators start, so power matters more than hours of autonomy. Thin pure lead plates give low internal resistance and high current per unit of volume. Capacity at the 8-hour rate is 205–1,040 Ah, and power at a 15-minute discharge to 1.67 V/cell is 764–1,150 W/cell. Below 5 minutes the blocks work inside their design zone, and the battery room comes out smaller than with AGM of the same power. The case is sealed (VRLA), needs no watering and fits cabinets or racks next to the UPS. Pure lead corrodes more slowly on continuous float, which matters for batteries that sit on float for years and discharge only during grid faults.

How to choose

Selection takes UPS power, inverter efficiency and runtime, then finds the block in the W/cell table. If you need longer runtime at a lower load, DataSafe HX at 4.8–123 Ah fits. For halls planned around lithium, look at DataSafe Noir with 500–600 kW cabinets for 5 minutes.

Request a price and lead time

DataSafe XE — 12 V TPPL batteries for sub-5-minute discharge in data centers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What discharge time is DataSafe XE built for?

The blocks are optimized for discharges under 5 minutes, typical of a UPS that only bridges until the generator starts.

What power rating does DataSafe XE have?

The range gives 764–1,150 W per cell at a 15-minute discharge to 1.67 V/cell.

What capacity do DataSafe XE batteries have?

At the 8-hour rate the range covers 205–1,040 Ah with 12 V blocks.

How does DataSafe XE differ from DataSafe HX?

XE is TPPL-based and aimed at large UPS systems in hyperscale data centers. HX blocks are smaller, 4.8–123 Ah, and fit mid-size UPS units and IT systems.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.