Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LIFEPO4 LITHIUM BATTERIES

PowerSafe V / V-TT / V-FT and SuperSafe T / T-TT / T-FT — VRLA batteries for telecom and UPS

PowerSafe V / V-TT / V-FT and SuperSafe T / T-TT / T-FT VRLA batteries are made for 2–12 V with 31–518 Ah (C10) and top or front terminals. The compact high-rate blocks back up telecom equipment, UPS systems and medical facilities.

Technology
VRLA, TPPL/AGM
Voltage
2–12 V
Capacity
V/V-TT 46–518 Ah; V-FT 31–190 Ah (C10)
Design
top (TT) and front (FT) terminals

Technical specifications

TechnologyVRLA, TPPL/AGM
Voltage2–12 V
CapacityV/V-TT 46–518 Ah; V-FT 31–190 Ah (C10)
Designtop (TT) and front (FT) terminals
Customs codes (for reference)
HS code8507.20
UKTZED code (Ukraine)8507208090
CN code (EU)85072080

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The suffix in the name marks terminal position, with TT for top terminals and FT for front terminals. The V and V-TT versions cover 46–518 Ah and the front-terminal V-FT 31–190 Ah, enough for anything from a small base station to a mid-size telecom node. The data list the line as TPPL/AGM, so it includes both thin plate pure lead blocks and conventional AGM. High current output matters for UPS and medical equipment, where the first minutes after a grid loss are critical. Front-terminal models go into telecom racks reachable only from the front, while top-terminal ones suit open racks and top-access cabinets. The case is sealed and needs no watering, so the blocks can sit in occupied rooms with ventilation to VRLA rules.

How to choose

Decide on the mounting method first. Front-access racks take V-FT or T-FT at 31–190 Ah, and open racks and cabinets V-TT or T-TT up to 518 Ah. For a pure power battery behind a UPS, DataSafe HX at 4.8–123 Ah is handier, and 48 V lithium backup comes from iON SC1048 / SC1548.

Request a price and lead time

PowerSafe V / V-TT / V-FT and SuperSafe T / T-TT / T-FT — VRLA batteries for telecom and UPS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What do the TT and FT suffixes in PowerSafe V mean?

TT means top terminals and FT front terminals. That decides which rack or cabinet the block fits.

What capacity does PowerSafe V-FT have?

Front-terminal V-FT comes in 31–190 Ah, and the V and V-TT versions in 46–518 Ah at the C10 rate.

Are SuperSafe T batteries suitable for medical facilities?

Yes, medical facilities are listed among the uses together with telecom and UPS.

What voltage are PowerSafe V blocks?

The line spans 2–12 V, so it includes both cells for rack batteries and monoblocks for cabinets.

What technology do PowerSafe V and SuperSafe T use?

They are VRLA batteries, listed as TPPL and AGM. No watering is required.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.