DataSafe HX / HX+ — 12 V VRLA batteries for UPS and data centers

DataSafe HX and HX+ sealed VRLA monoblocks run at 12 V, span 4.8 to 129 Ah and deliver up to 1,000 W per cell over a 15-minute discharge. They go into UPS systems, IT equipment, emergency lighting and security systems, while HX+ targets data centers that need higher energy efficiency.

Technology
HX: AGM; HX+: thin plate pure lead (TPPL)
Voltage
12 V
Capacity
HX 4.8–123 Ah; HX+ 129 Ah (8 h to 1.75 V/cell)
Power
HX 23–1,000 W/cell, HX+ 360–660 W/cell (15 min to 1.67 V/cell)

Technical specifications

TechnologyHX: AGM; HX+: thin plate pure lead (TPPL)
Voltage12 V
CapacityHX 4.8–123 Ah; HX+ 129 Ah (8 h to 1.75 V/cell)
PowerHX 23–1,000 W/cell, HX+ 360–660 W/cell (15 min to 1.67 V/cell)
Designtop and front terminals
Customs codes (for reference)
HS code8507.20
UKTZED code (Ukraine)8507208090
CN code (EU)85072080

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The line uses two technologies. HX is built as AGM, with the electrolyte held in a glass-mat separator, and HX+ uses thin plates of pure lead (TPPL). HX capacity runs 4.8–123 Ah, and HX+ is rated 129 Ah at the 8-hour rate to 1.75 V/cell. Power figures are quoted for a 15-minute discharge to 1.67 V/cell, with HX at 23–1,000 W/cell and HX+ at 360–660 W/cell. These figures drive UPS string sizing, since a UPS draws energy in short heavy bursts rather than over hours. The sealed high-rate blocks need no watering and can sit in closed cabinets next to IT gear. Both top-terminal and front-terminal versions exist, and the latter suits racks where the blocks are reachable only from the front.

How to choose

Start the selection from power per cell at the required runtime, because Ah capacity is secondary here. Smaller HX blocks cover small UPS units and emergency lighting, while data center battery cabinets call for HX+ with its 129 Ah. For discharges shorter than 5 minutes and capacities from 205 Ah, look at DataSafe XE, and for 8–40 Ah top-terminal blocks DataSafe NPX fits better.

Request a price and lead time

DataSafe HX / HX+ — 12 V VRLA batteries for UPS and data centers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What capacity do DataSafe HX and HX+ batteries have?

HX comes in 4.8–123 Ah, and HX+ is rated 129 Ah. Both figures refer to the 8-hour rate to 1.75 V/cell.

How does DataSafe HX+ differ from HX?

HX+ is built on thin pure lead plates (TPPL) and delivers 360–660 W/cell over 15 minutes. The standard HX is AGM and covers a broader 23–1,000 W/cell range.

What is the voltage of a DataSafe HX monoblock?

Each monoblock is rated 12 V. Blocks are wired in series for the UPS DC bus, and the block count follows from the inverter nominal DC voltage.

Can DataSafe HX go into a rack with front-only access?

Yes, the series includes a front-terminal version. Cabinets with top access take the top-terminal blocks.

Do DataSafe HX batteries need maintenance?

They are sealed VRLA batteries, so there is no watering or electrolyte density check. Block voltage and cabinet temperature still need periodic checks.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.