Multi Switch, Multi Pass, Multi Socket PDU — ATS, bypasses and PDUs for racks 10–30 A

Multi Switch rack ATS units rated 16 and 30 A, Multi Socket PDUs and Multi Pass bypasses build redundant rack power for IT equipment. The ATS moves the load between two mains supplies or two UPS units automatically, and Multi Pass takes a UPS out for service via a manual bypass.

Multi Switch
16 A ATS, 8 IEC 10 A outputs, 19″
Multi Switch ATS
16 A (8×IEC 10 A or 1×IEC 16 A) and 30 A (4×IEC 10 A + 1×IEC 16 A or terminals)
Multi Socket PDU
1U, 16 A input, 8 IEC outlets up to 4 A, remote on/off for each outlet
Multi Pass
manual maintenance bypass: 10/16 A wall-mounted, 16 A rack-mounted; MBB 125 A 4P, MBB 100 A 2P

Technical specifications

Multi Switch16 A ATS, 8 IEC 10 A outputs, 19″
Multi Switch ATS16 A (8×IEC 10 A or 1×IEC 16 A) and 30 A (4×IEC 10 A + 1×IEC 16 A or terminals)
Multi Socket PDU1U, 16 A input, 8 IEC outlets up to 4 A, remote on/off for each outlet
Multi Passmanual maintenance bypass: 10/16 A wall-mounted, 16 A rack-mounted; MBB 125 A 4P, MBB 100 A 2P
Protectiondisconnection of an outlet group on load short circuit; backfeed protection (Multi Pass)
Communicationnetwork card slot (HTTP, SNMP, SSH), compatible with PowerShield³ and PowerNetGuard
Customs codes (for reference)
HS code8536.50
UKTZED code (Ukraine)8536508000
CN code (EU)85365080

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The base Multi Switch in a 19″ housing has 8 IEC 10 A outputs and feeds single-corded equipment from two inputs. The 16 A Multi Switch ATS feeds 8 IEC 10 A outlets or one IEC 16 A outlet, and the 30 A version through 4 IEC 10 A outlets plus one IEC 16 A outlet or through terminals. The 1U Multi Socket PDU takes a 16 A input and spreads it over 8 IEC outlets of up to 4 A, each switchable remotely. Multi Pass comes wall-mounted for 10/16 A and rack-mounted for 16 A, plus MBB 125 A 4P and MBB 100 A 2P modules. A load short circuit trips only its outlet group, and Multi Pass has backfeed protection. The slot takes a network card with HTTP, SNMP and SSH.

How to choose

Start from the total rack current. Up to 16 A the Multi Switch ATS 16 A will do, at 30 A take the larger version with terminals, and the single IEC 16 A outlet variant suits a few 16 A loads. Multi Pass is picked by UPS rating and mounting place, with MBB 100 and 125 A for a larger UPS panel. Above 30 A, or for three-phase loads, move to the Master Switch MTS static switch rated 100–800 A.

Request a price and lead time

Multi Switch, Multi Pass, Multi Socket PDU — ATS, bypasses and PDUs for racks 10–30 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What current ratings does the Multi Switch ATS come in?

There are 16 A and 30 A versions. The 30 A unit has 4 IEC 10 A outlets and one IEC 16 A outlet, or terminals.

Can Multi Socket PDU outlets be switched off remotely?

Yes, each of the 8 IEC outlets up to 4 A switches on and off remotely. The PDU input is 16 A.

What is the Multi Pass maintenance bypass for?

It feeds the load around the UPS during service. Options are wall-mounted 10/16 A, rack-mounted 16 A and MBB modules for 125 and 100 A.

How is a Multi Switch monitored over the network?

A network card with HTTP, SNMP and SSH in the slot puts the ATS into PowerShield³ and PowerNetGuard next to the UPS units.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.