MVS6400-LV / MVS8960-LV — medium-voltage station for 1,500 V string inverters
Country: China · Model: MVS6400-LV / MVS8960-LV
The MVS8960-LV medium-voltage station carries an oil-immersed 8,960 kVA transformer rated at 40 °C, steps 0.8 kV up to 20–35 kV and gathers SG350HX 1,500 V string inverters into a block of up to 9.8 MW. Everything is installed in a standard container that reaches the field ready for cable connection.
- Transformer (MVS8960-LV)
- oil-immersed, 8,960 kVA at 40 °C (up to 9,856 kVA at 30 °C)
- Voltage
- 0.8 kV / 20–35 kV, Dy11y11
- Block
- up to 9.8 MW
- Protection rating
- IP54
Technical specifications
| Transformer (MVS8960-LV) | oil-immersed, 8,960 kVA at 40 °C (up to 9,856 kVA at 30 °C) |
|---|---|
| Voltage | 0.8 kV / 20–35 kV, Dy11y11 |
| Block | up to 9.8 MW |
| Protection rating | IP54 |
| Operating temperature | −30 to +60 °C |
| Dimensions / weight | 6,058 × 2,896 × 2,438 mm, ~24 t |
| Customs codes (for reference) | |
| HS code | 8537.20 |
| UKTZED code (Ukraine) | 8537209100 (1–72.5 kV) |
| CN code (EU) | 85372091 (1–72.5 kV) |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
At 30 °C the transformer carries up to 9,856 kVA, so in the cool season the block can run above its 40 °C rating. Vector group Dy11y11 means a delta medium-voltage winding and two star-connected 0.8 kV windings, each feeding its own group of inverters. The MV and LV compartments are isolated from each other, so the 0.8 kV side is serviced without access to the 20–35 kV switchgear. IP54 protection and a −30 to +60 °C operating range suit open installation right on the PV field. The 6,058 × 2,896 × 2,438 mm footprint matches a 20-ft High Cube container, and at about 24 t it travels on a low-bed trailer and is set by crane on a prepared base. The smaller MVS6400-LV completes the line for lower-power blocks.
How to choose
Size the station by the total inverter power in the block and by the voltage of the line it connects to. The MVS8960-LV is built for a 0.8 kV input, which is the SG350HX output, and for a 20–35 kV grid, while a smaller block takes the MVS6400-LV. If the same site gets a BESS, the standard PowerTitan ST2236UX block has its own SC4000UD-MV PCS and a 4,000 kVA 0.8/33 kV transformer, so the storage usually connects through a separate bay.
Request a price and lead time
MVS6400-LV / MVS8960-LV — medium-voltage station for 1,500 V string inverters. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the transformer rating of the MVS8960-LV?
8,960 kVA at 40 °C and up to 9,856 kVA at 30 °C.
Which inverters connect to the MVS8960-LV?
SG350HX string inverters at 1,500 V with a 0.8 kV output, assembled into a block of up to 9.8 MW.
How much does the MVS station weigh?
About 24 t, with dimensions of 6,058 × 2,896 × 2,438 mm.
What vector group does the MVS8960-LV transformer use?
Dy11y11, with a delta medium-voltage winding and two star-connected 0.8 kV windings.
What operating conditions is the MVS8960-LV rated for?
A range of −30 to +60 °C with IP54 protection, so the station stands in the open field without a shelter.