egeSmart:Integrity DCS gas pipe with an early damage detection system (electrical signal tapes), OD 25–630 mm
Country: · Model: egeSmart:Integrity DCS
Monitored gas pipe egeSmart:Integrity DCS of PE 100-RC with electrical signal tapes and a PEplus protective layer, outside diameter 25–630 mm, SDR 11 and 17. The system detects damage at an early stage and shows its location throughout the service life of the pipeline. This helps prevent gas losses, for example from damage by third-party machinery during earthworks.
- Outside diameter
- 25 … 630 mm
- SDR
- 11, 17 (others on request)
- Service pipe
- PE 100-RC
- Protective sheath
- PEplus, orange-yellow
Technical specifications
| Outside diameter | 25 … 630 mm |
|---|---|
| SDR | 11, 17 (others on request) |
| Service pipe | PE 100-RC |
| Protective sheath | PEplus, orange-yellow |
| Monitoring | electrical signal tapes; continuous or battery-powered interval monitoring |
| Standards | DIN 8074/8075, EN 1555, DVGW GW 335 |
| Testing | TÜV SÜD MUC-KSP-A 3003 |
| Supply | straight lengths 6, 12, 20 m; coils 100 m; drums |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The pipe has three layers: a service pipe of PE 100-RC, electrical signal tapes and an orange-yellow PEplus protective layer. After the sheath is damaged, the electrical state of the tapes changes and the monitoring system reports the event, while automatic measures make it possible to avoid major accidents and expensive repair. Monitoring can be continuous or at intervals, with battery power. The same protective layer makes trenchless laying and an integrity check after laying possible. The pipe complies with DIN 8074/8075, EN 1555 and DVGW GW 335, with TÜV SÜD tests MUC-KSP-A 3003. Supply is in straight lengths of 6, 12 or 20 m, in 100 m coils and on drums. Laying methods include drilling, relining, pipe bursting, piercing, plough, cutter and trench. All pipes of the line carry the H2ready mark, and the DBI institute confirmed tests with 100% hydrogen.
How to choose
The system is taken for critical sections where the operator needs early diagnostics and documented condition, in particular in urban development and at crossings. If an integrity check at laying and route location are enough, SLM DCT will do, and if digital data along the route and diameters from 63 to 630 mm are needed, look at egeSmart:Data.
Request a price and lead time
egeSmart:Integrity DCS gas pipe with an early damage detection system (electrical signal tapes), OD 25–630 mm. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How does egeSmart:Integrity DCS detect damage?
After the sheath is damaged, the electrical state of the signal tapes changes, and the monitoring system reports the event and its location.
Which monitoring mode can be chosen?
Continuous monitoring or interval monitoring with battery power.
What diameters and SDRs does the system have?
Outside diameter from 25 to 630 mm, SDR 11 and 17, other SDRs on request.
Is the system suitable for hydrogen?
All gas pipes of the line carry the H2ready mark, and the DBI institute confirmed tests with 100% hydrogen.