egeSmart:Data PE 100-RC gas pipe with a fiber-optic detection layer for digital monitoring, OD 63–630 mm

egeSmart:Data gas pipe of PE 100-RC with a fiber-optic detection layer and a PEplus protective sheath, outside diameter 63–630 mm, SDR from 17.6 to 7.4. It provides digital data on condition along the whole route and locates damage to within a meter. Data go to SCADA and cloud systems.

Outside diameter
63 … 630 mm
SDR
17.6 … 7.4
Service pipe
PE 100-RC
Detection layer
with a fiber-optic conductor (in the water version: an aluminium electrically conductive barrier layer)

Technical specifications

Outside diameter63 … 630 mm
SDR17.6 … 7.4
Service pipePE 100-RC
Detection layerwith a fiber-optic conductor (in the water version: an aluminium electrically conductive barrier layer)
Protective sheathPEplus
Functionsearly detection of leaks, anomalies and external impacts; localization to within a meter; integration into SCADA and cloud
Supplystraight lengths 12, 20, 30 m; coils; drums

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The pipe has a service layer of PE 100-RC, a detection layer with a fiber-optic conductor and an outer sheath of PEplus. Continuous monitoring detects leaks and operating deviations at an early stage. Mechanical impacts, intervention by third parties or tampering attempts are visible in advance and can be assessed immediately. Damage locations are pinpointed to within a meter, even under hard surfacing and in hard-to-reach sections. One infrastructure serves both leak monitoring and data transmission. An SDR from 17.6 to 7.4 makes it possible to choose the pipe for the required working pressure. Supply is in straight lengths of 12, 20 or 30 m, in coils and on drums, other lengths on request. Laying methods include horizontal directional drilling, relining, pipe bursting, piercing, plough, cutter and trench. The PE 100-RC material is resistant to natural gas and condensate per EN 1555, all gas pipes of the line carry the H2ready mark, and the DBI institute confirmed tests with 100% hydrogen.

How to choose

egeSmart:Data is chosen when the operator needs transparency of the condition of the whole network, not just a damage alarm. Diameters are from 63 to 630 mm, and the SDR is selected for the working pressure. If electrical monitoring is enough, look at egeSmart:Integrity DCS or SLM DCT for 25–630 mm.

Request a price and lead time

egeSmart:Data PE 100-RC gas pipe with a fiber-optic detection layer for digital monitoring, OD 63–630 mm. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What exactly does egeSmart:Data monitor?

The fiber-optic conductor detects leaks, operating deviations, mechanical impacts and intervention by third parties along the whole route.

How accurately is the damage location determined?

To within a meter, even under hard surfacing and in hard-to-reach sections.

Where are the monitoring data sent?

To SCADA and cloud systems. The same infrastructure is used both for leak monitoring and for data transmission.

What is the range of diameters and SDRs?

Outside diameter 63–630 mm, SDR from 17.6 to 7.4.

In what form is the pipe supplied?

In straight lengths of 12, 20 or 30 m, in coils and on drums at the customer's request, other lengths on request.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.