Multicluster Box — distribution cabinet for Sunny Island systems

The Multicluster Box distribution cabinet combines 2 to 12 three-phase clusters of 3 Sunny Island inverters each into an off-grid system of up to 360 kW. In backup systems it handles installations up to 138 kWp, and it leaves the factory fully assembled.

Configuration
2–12 three-phase clusters of 3 Sunny Island each
Off-grid system power
up to 360 kW
Backup systems
up to 138 kWp
Design
fully factory-assembled

Technical specifications

Configuration2–12 three-phase clusters of 3 Sunny Island each
Off-grid system powerup to 360 kW
Backup systemsup to 138 kWp
Designfully factory-assembled
More from the manufacturer’s documentation
ModelsMC-Box 6 (MC-BOX-6.3-11), MC-Box 12 (MC-BOX-12.3-20), MC-Box 36 (MC-BOX-36.3-11), Grid-Connect-Box 12
Rated voltage230 V (L–N) / 400 V (L–L)
AC voltage range (L–N)172.5–250 V (MC-Box 6, 36); 172.5–265 V (MC-Box 12)
Frequency50 Hz, 40–70 Hz (MC-Box 6, 36); 50 / 60 Hz, 45–65 Hz (MC-Box 12)
Number of Sunny Island units6 (MC-Box 6), 12 (MC-Box 12), 36 (MC-Box 36)
Sunny Island power (rated / at 45 °C)36 / 32 kW (MC-Box 6), 72 / 65 kW (MC-Box 12), 216 / 195 kW (MC-Box 36)
Load connection55 kW, 3 × 80 A (MC-Box 6); 138 kW, 3 × 200 A (MC-Box 12); 300 kW, 3 × 435 A (MC-Box 36)
Generator connection55 kW (MC-Box 6), 138 kW (MC-Box 12), 300 kW (MC-Box 36)
PV connection55 kW (MC-Box 6), 138 kW (MC-Box 12), 360 kW, 3 × 522 A (MC-Box 36)
FusesNH00 (MC-Box 6), NH1 (MC-Box 12), NH3 (MC-Box 36); C40 A circuit breaker per Sunny Island
Grid configurationTN-S (MC-Box 6, 36); TN-S, TN-C-S, TT (MC-Box 12)
Dimensions (W × H × D)760 × 760 × 210 mm (MC-Box 6); 1,200 × 1,600 × 435 mm (MC-Box 12); 1,200 × 2,000 × 800 mm (MC-Box 36); 600 × 1,400 × 435 mm (Grid-Connect-Box 12)
Weight55 kg (MC-Box 6), 200 kg (MC-Box 12), 400 kg (MC-Box 36), 103 kg (Grid-Connect-Box 12)
Mountingsuspended (MC-Box 6), base-mounted (others)
Operating temperature−25 °C to +50 °C (MC-Box 6); −25 °C to +60 °C (others)
Degree of protectionIP65 (MC-Box 6), IP55 (MC-Box 12), IP54 (MC-Box 36)
Relative humidity0–100% non-condensing
Installation altitude≤ 2,000 m
Functionsload-shedding contactor, automatic generator bypass, active anti-islanding, reverse current monitoring
Warranty5 years
CertificatesCE
Customs codes (for reference)
HS code8537.10
UKTZED code (Ukraine)8537109890
CN code (EU)85371098

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Battery inverter clusters, a diesel generator, loads and renewable sources all terminate in the cabinet. This is how off-grid networks and hybrid systems are built, with the generator and PV modules feeding a common 230 / 400 V bus. Only the external lines remain to connect on site, which saves switchboard assembly and switching design work. A load-shedding contactor, automatic generator bypass, active anti-islanding and reverse current monitoring are already inside. Each Sunny Island has its own C40 A breaker, and the feeders run through NH00, NH1 or NH3 fuses depending on cabinet size. The small MC-Box 6 weighs 55 kg and hangs on a wall, the MC-Box 12 and MC-Box 36 stand on the floor, at altitudes up to 2,000 m.

How to choose

Cabinet size follows the number of Sunny Island units, 6, 12 or 36. The MC-Box 6 is rated for 36 kW of inverter power and a 55 kW load at 3 × 80 A, the MC-Box 12 for 72 kW and 138 kW at 3 × 200 A, and the MC-Box 36 for 216 kW and 300 kW at 3 × 435 A. In a hot room use the 45 °C rating, which is 195 kW for the MC-Box 36. A single Sunny Island 6.0H / 8.0H cluster up to 24 kW does not need a multicluster cabinet.

Request a price and lead time

Multicluster Box — distribution cabinet for Sunny Island systems. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many Sunny Island clusters connect to the Multicluster Box?

From 2 to 12 three-phase clusters, each with 3 Sunny Island units, so up to 36 inverters in the MC-Box 36.

What off-grid system power does the Multicluster Box support?

Up to 360 kW in off-grid systems and up to 138 kWp in backup systems. The PV input of the MC-Box 36 is rated 360 kW at 3 × 522 A.

Does the Multicluster Box need assembly on site?

No, the cabinet is fully assembled at the factory and the installer only connects external cables.

Which earthing systems does the Multicluster Box support?

The MC-Box 12 works with TN-S, TN-C-S and TT. The MC-Box 6 and MC-Box 36 are for TN-S only.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.