SE electronic voltage stabilizer 1–2000 kVA

SE electronic stabilizers cover a single-phase range of 1–75 kVA and a three-phase range of 3–2000 kVA, and hold the output within ±3% at 98% efficiency. They are installed at the input of enterprises, administrative buildings and process lines where the supply sags by up to −30%.

Power
1-phase 1–75 kVA (SE-10…SE-23); 3-phase 3–2000 kVA (SE-10/3…SE-34/3)
Input voltage
220/230/240 V −30% +20% (1-ph.); 380/400/415 V −30% +20% (3-ph.); others on request
Output voltage
±3%, sine wave without added distortion
Efficiency at full load
98%

Technical specifications

Power1-phase 1–75 kVA (SE-10…SE-23); 3-phase 3–2000 kVA (SE-10/3…SE-34/3)
Input voltage220/230/240 V −30% +20% (1-ph.); 380/400/415 V −30% +20% (3-ph.); others on request
Output voltage±3%, sine wave without added distortion
Efficiency at full load98%
Response time2 ms (smaller models 0.15 s)
Principleseries (buck-boost) transformer, triacs, microprocessor control
Protection degreeIP20
Operating temperature−22…+50 °C
StandardsCE (2014/30/EU, 2014/35/EU), IEC 742

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The continuous-mode circuit is built around a series buck-boost transformer, to whose primary winding triacs apply the required share of voltage under microprocessor control. Only the correction passes through the power path, not the whole load, so losses are small and the output sine wave gets no added distortion. The input range is 220/230/240 V −30% +20% for single-phase units and 380/400/415 V −30% +20% for three-phase units; other ratings are made to order. Most models respond in 2 ms, smaller ones in 0.15 s. The IP20 enclosure is intended for an electrical room, and the operating temperature of −22…+50 °C allows the unit to be installed in an unheated room as well. CE conformity is confirmed under directives 2014/30/EU and 2014/35/EU, and the transformer design complies with IEC 742.

How to choose

The model is set by the load power: single-phase SE-10…SE-23 cover 1–75 kVA, while three-phase SE-10/3…SE-34/3 reach 2000 kVA. For a single device up to 5 kVA the more compact SH with ±2% accuracy is suitable. If the line has a lot of interference besides voltage deviations, take the CR power conditioner with the same power range. For a solar plant that is tripped by protection because of high voltage at the connection point, there is the bidirectional SE Solar version.

Request a price and lead time

SE electronic voltage stabilizer 1–2000 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the stabilization accuracy of SE?

The output voltage is held within ±3%, and the sine wave gets no added distortion.

What mains deviation does the SE stabilizer compensate?

The permitted input is −30% +20% of the 220/230/240 V rating for single-phase and 380/400/415 V for three-phase models.

How fast does the SE stabilizer respond?

The response time is 2 ms, and 0.15 s for the smaller models of the range.

Can the SE stabilizer be installed in an unheated room?

The operating temperature range is −22…+50 °C, so the unit withstands an unheated electrical room. The IP20 protection degree requires shelter from dust and moisture.

What is the efficiency of the SE stabilizer?

At full load the efficiency is 98%, because only the correction power passes through the triacs.

Similar products

Voltage stabilizers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.