PowerSave ESS energy-saving voltage regulator (optimizer)
Country: · Model: PowerSave ESS
PowerSave ESS energy-saving voltage regulator holds the output voltage at a reduced level, for example 220 or 210 V. Typical electricity saving is 5–10%. It is installed in hotels, in production and in agriculture ahead of lighting, pumps and ventilation.
- Principle
- stabilizing the output voltage at a reduced level (for example, 220 or 210 V)
- Electricity saving
- typically 5–10%
- Example
- reduction of 233–244 V to a stable 215 V on all phases, saving 15.7% (Radisson Roe Park)
- Manufacture
- designed and made in the UK
Technical specifications
| Principle | stabilizing the output voltage at a reduced level (for example, 220 or 210 V) |
|---|---|
| Electricity saving | typically 5–10% |
| Example | reduction of 233–244 V to a stable 215 V on all phases, saving 15.7% (Radisson Roe Park) |
| Manufacture | designed and made in the UK |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Mains voltage is often higher than the equipment needs, and the excess turns into losses. The optimizer lowers it and holds it stable at a set level, so the load consumes less and the service life of lighting, pumps and ventilation grows. A real example is the Radisson Roe Park hotel, where a voltage of 233–244 V was reduced to a stable 215 V on all phases. The electricity saving there was 15.7%, while the typical value for such installations is 5–10%. The output level is set based on the load requirements, for example 220 or 210 V. The device is designed and made in the UK.
How to choose
First find out whether you need saving or exactly the nominal voltage. The optimizer suits cases where the network voltage is high and the equipment works normally at a reduced level, for example 215 V. If a 230 V output is needed with input fluctuations, take a stabilizer, the single-phase TS at 0.99–48.6 kVA or the SVR at 5–400 kVA. For three-phase loads at 2.97–146 kVA there is the TS with independent regulation of each phase.
Request a price and lead time
PowerSave ESS energy-saving voltage regulator (optimizer). We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How much electricity does PowerSave ESS save?
Typically 5–10%. At the Radisson Roe Park hotel, when 233–244 V was reduced to 215 V, the saving was 15.7%.
How does a voltage optimizer differ from an ordinary stabilizer?
It holds the output at a deliberately reduced level, for example 220 or 210 V, to cut consumption. An ordinary stabilizer maintains the nominal value.
Which equipment benefits from reduced voltage?
Lighting, pumps and ventilation. Their consumption falls and their service life is extended.
Where is PowerSave ESS used?
In hotels, in production and in agriculture.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.