Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

VOLTAGE STABILIZERS

Single-phase inverter voltage stabilizers 11–17.6 kW (Quant-11, -14, -18) for industry

Single-phase inverter voltage stabilizers rated 11, 13.8 and 17.6 kW maintain a nominal 220 or 230 V output at input voltages from 90 to 350 V. They are designed for workshops, production floors, offices and solar power plants where the mains voltage fluctuates and the equipment is sensitive to voltage variations. Regulation is stepless and includes proactive protection: the stabilizer disconnects the load before a dangerous voltage reaches it. Several modules can be combined into three-phase clusters.

Models and power
Quant-11 — 11 kW; Quant-14 — 13.8 kW; Quant-18 — 17.6 kW (at 220 V input)
Power at 110 V input
approximately half the rated value (Quant-11 — 5.5 kW)
Current (Quant-11)
rated 50 A, overload/short circuit 100 A
Module weight (Quant-11)
approx. 11 kg

Technical specifications

Models and powerQuant-11 — 11 kW; Quant-14 — 13.8 kW; Quant-18 — 17.6 kW (at 220 V input)
Power at 110 V inputapproximately half the rated value (Quant-11 — 5.5 kW)
Current (Quant-11)rated 50 A, overload/short circuit 100 A
Module weight (Quant-11)approx. 11 kg
Self-consumption (Quant-11)21 W
Input voltage90–350 V
Output voltage220 or 230 V (selectable), correction ±3 % in 0.1 % steps
Stabilization accuracy0.5 %
Mains frequency50 ± 5 Hz
Overload shutdown>125–150 % — 12 s; >150 % / short circuit — 1.5 s
Start-up delay6 s
Operating temperature+5…+40 °C, humidity 40–80 %
Protection ratingIP20
Coolingforced, low-noise
Module (H×W×D)435 × 250 × 125 mm
Mountingwall-mounted

Analogues in the catalogue

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Main features: inverter circuit with double conversion: surges and pulses at the input do not pass to the output; smooth regulation without steps and without delay — lamps do not flicker; reactive current compensation and current limiting, voltage waveform improvement; interference filter and pulse absorber; built-in display and power measurement, mechanical bypass; operation from a generator is not supported.

Technical data: Models and power — Quant-11 — 11 kW; Quant-14 — 13.8 kW; Quant-18 — 17.6 kW (at 220 V input); Power at 110 V input — approximately half the rated value (Quant-11 — 5.5 kW); Current (Quant-11) — rated 50 A, overload/short circuit 100 A; Module weight (Quant-11) — approx. 11 kg; Self-consumption (Quant-11) — 21 W; Input voltage — 90–350 V; Output voltage — 220 or 230 V (selectable), correction ±3 % in 0.1 % steps; Stabilization accuracy — 0.5 %; Mains frequency — 50 ± 5 Hz; Overload shutdown — >125–150 % — 12 s; >150 % / short circuit — 1.5 s; Start-up delay — 6 s; Operating temperature — +5…+40 °C, humidity 40–80 %; Protection rating — IP20; Cooling — forced, low-noise; Module (H×W×D) — 435 × 250 × 125 mm; Mounting — wall-mounted.

Application: production shops and workshops; machine tools, compressors, pumps and other three-phase loads; facilities with solar power plants; networks with large voltage fluctuations (90–350 V).

How to choose

We select the power rating, version (with or without a phase control unit, PCU) and equipment set to suit the load; delivery time depends on the production workload, so please clarify with the manager.

Similar products

Voltage stabilizers

Request a price and lead time

Single-phase inverter voltage stabilizers 11–17.6 kW (Quant-11, -14, -18) for industry, quant. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.