Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

VOLTAGE STABILIZERS

PWM — single-phase digital static voltage stabiliser 2.1–14 kVA

The PWM digital single-phase stabiliser of 2.1–14 kVA gives 230 V ±1 % at an input voltage of 173–287 V. It is designed for IT and telecom equipment, that is, server cabinets, communication nodes and UPS racks.

Power
2.1–14 kVA
Input voltage
173–287 V
Output accuracy
230 V ±1 %
Response time
within 200 ms

Technical specifications

Power2.1–14 kVA
Input voltage173–287 V
Output accuracy230 V ±1 %
Response timewithin 200 ms
Efficiency≥ 95 %
TechnologyPWM, static electronic

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Voltage is regulated by pulse-width modulation (PWM), a static electronics design without brushes or a servo motor. Correction takes place within 200 ms. Such output accuracy is useful when an online UPS stands behind the stabiliser, because with an even input voltage it switches to battery less often. Efficiency is at least 95 %, so in a closed server room the unit adds little heat. The lower limit of 173 V corresponds to a grid sag of about a quarter, and on rural lines with deeper dips a different unit will be needed. The compact enclosures are placed next to a rack or on the floor of the server room.

How to choose

The model is chosen by the full load power in kVA, allowing for the UPS charging current. If the grid at the site drops below 173 V, it is better to take the ESR with an input range of up to ±50 % for 3–100 kVA. For household appliances up to 5 kVA the simpler VR is enough.

Request a price and lead time

PWM — single-phase digital static voltage stabiliser 2.1–14 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What output voltage accuracy does the PWM stabiliser give?

230 V ±1 %, which suits IT and telecom equipment with a narrow supply tolerance.

At what input voltage does the PWM work?

The stabiliser holds the output at an input voltage from 173 to 287 V, so it copes with both sags and high voltage at night.

How quickly does the PWM respond to a voltage change?

Correction takes place within 200 ms after a change of voltage in the grid, and for server power supplies such a transition is unnoticeable.

Is it worth installing the PWM stabiliser in front of a UPS?

Yes, a stable input reduces the number of UPS transfers to battery and preserves battery life.

What is the efficiency of the PWM stabiliser?

At least 95 %, so even at a 14 kVA load the heat output remains moderate.

Similar products

Voltage stabilizers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.