Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

VOLTAGE STABILIZERS

SH voltage stabilizer 100 VA – 5 kVA

The SH single-phase stabilizer, rated from 100 VA to 5 kVA, holds the output voltage with ±2% accuracy. It is installed next to an individual consumer, for example a controller, a measuring instrument, a server rack or a boiler.

Power
100 VA – 5 kVA (SH-1…SH-10)
Phases
single-phase
Input voltage
220/230/240 V ±20% (100–127 V on request)
Output voltage
±2%, THD < 3%

Technical specifications

Power100 VA – 5 kVA (SH-1…SH-10)
Phasessingle-phase
Input voltage220/230/240 V ±20% (100–127 V on request)
Output voltage±2%, THD < 3%
Efficiency at full load75%
Response time0.01–0.04 s
Protection degreeIP20
StandardsCE, IEC 742

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The range consists of models SH-1…SH-10; the input is rated for 220/230/240 V ±20%, and for 100–127 V networks the manufacturer makes a version to order. The total harmonic distortion at the output is below 3%, so the stabilizer suits electronics with switch-mode power supplies and measuring circuits. The response time is 0.01–0.04 s, so short mains dips are almost unnoticed by the consumer. Efficiency at full load is 75%, part of the power is dissipated as heat, and free space for cooling is needed around the enclosure. The IP20 enclosure is intended for indoor use, and the unit meets CE and IEC 742 requirements.

How to choose

The SH rating is chosen from the rated power of the consumer with a margin for starting currents, especially for pumps and compressors. When the load exceeds 5 kVA or a three-phase input is needed, move to SE, with a range of 1–75 kVA single-phase and 3–2000 kVA three-phase, where efficiency reaches 98%. For sensitive lines that also suffer from mains interference, the CR power conditioner is suitable.

Request a price and lead time

SH voltage stabilizer 100 VA – 5 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power do SH stabilizers have?

The SH-1…SH-10 range covers 100 VA – 5 kVA in single-phase versions.

What is the output voltage accuracy of the SH stabilizer?

The output is held within ±2% with total harmonic distortion below 3%.

Is there an SH version for 100–127 V networks?

Yes, the standard input is 220/230/240 V ±20%, and a 100–127 V version is made to order.

Why is the efficiency of the SH stabilizer 75%?

This is the value at full load for a low-power unit. Losses turn into heat, so the stabilizer is not placed in a closed niche without ventilation.

How fast does SH respond to a voltage change?

The response time is 0.01–0.04 s, so short mains dips are compensated almost unnoticed by the consumer.

Similar products

Voltage stabilizers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.