Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

VOLTAGE STABILIZERS

Sirius advance three-phase voltage stabilizer with reactive power compensation 60–4000 kVA

Sirius advance is a three-phase voltage stabilizer of 60–4000 kVA with a built-in reactive power regulator. The output is held within 210–255 V phase-to-neutral with an accuracy of ±0.5 %. It is for power and infrastructure sites where one cabinet must level the voltage and raise the power factor.

Power
60–4000 kVA
Output voltage
210–255 V (phase-neutral) / 360–440 V (line)
Accuracy
±0.5 %
Overload
200 % for 2 min

Technical specifications

Power60–4000 kVA
Output voltage210–255 V (phase-neutral) / 360–440 V (line)
Accuracy±0.5 %
Overload200 % for 2 min
Built inreactive power regulator
Control10″ touch panel, Modbus, XCloud

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The model extends the basic Sirius series with a reactive power regulator, so a separate compensation unit is not needed on site. The phase output voltage lies within 210–255 V, the line voltage within 360–440 V, and the error does not exceed ±0.5 %. The stabilizer withstands an overload of 200 % for 2 min, which is enough for motor starting currents and short-term load surges. Control is on a 10″ touch panel, and for communication with the control room there are Modbus and the XCloud cloud service. The upper limit of the range, 4000 kVA, means the unit can be installed both at the input of a large workshop and at an infrastructure site.

How to choose

Select the rating by the full load power, and calculate the reserve from the overload of 200 % for 2 min. If a reactive power regulator is not needed, look at the Odyssey of 80–4000 kVA, which holds 110 % continuously and 120 % for 60 s. For loads up to 120 kVA the Aquarius of 10–120 kVA is enough, and for sensitive electronics on a single-phase line the Gemini of 4–40 kVA.

Request a price and lead time

Sirius advance three-phase voltage stabilizer with reactive power compensation 60–4000 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does Sirius advance have?

The range covers 60–4000 kVA. For smaller loads the Aquarius of 10–120 kVA or the Gemini of 4–40 kVA will do.

Why does a stabilizer need a built-in reactive power regulator?

Besides voltage, the unit also handles the reactive component, so at a site with a low power factor a separate compensation cabinet does not have to be installed.

What overload does Sirius advance withstand?

200 % for 2 min is allowed. For comparison, the Odyssey works with 110 % continuously and 120 % for 60 s.

What is the output voltage and with what accuracy?

210–255 V between phase and neutral, which corresponds to 360–440 V line. The accuracy is ±0.5 %.

How can the stabilizer be connected to a supervisory system?

Via Modbus or the XCloud cloud. Locally, the 10″ touch panel is used.

Similar products

Voltage stabilizers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.