The manufacturer iVolt — voltage optimizer
Country: United Kingdom · Model: iVolt
The iVolt voltage optimizer lowers the supply voltage of a site to the level the equipment needs and saves up to 25 % of electricity. Payback is usually 2–3 years, so the unit is installed at the entry of offices, shops and production premises.
- Technology
- microprocessor, thyristors, transformer; > 3000 measurements/s
- Efficiency
- > 99.4 % at full load
- Savings
- up to 25 %
- Monitoring
- built-in IRT Energy Monitor
Technical specifications
| Technology | microprocessor, thyristors, transformer; > 3000 measurements/s |
|---|---|
| Efficiency | > 99.4 % at full load |
| Savings | up to 25 % |
| Monitoring | built-in IRT Energy Monitor |
| Production | 's own factories, ISO 9001 |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Motors, lamps and refrigeration compressors at an overstated mains voltage consume more than they need to work, and the iVolt removes this excess. The circuit combines a transformer, thyristor switches and a microprocessor that makes more than 3000 measurements per second and adjusts the output when the input voltage changes. An efficiency above 99.4 % at full load means that the unit's own losses hardly eat into the savings. The built-in IRT Energy Monitor keeps track of consumption, so the actual savings are checked from the data of the device itself. The units are made at the manufacturer's own factories with an ISO 9001 quality system.
How to choose
The iVolt power is selected by the maximum load of the entry, and the savings are estimated from the actual mains voltage. The higher the voltage at the entry relative to the equipment rating, the closer the result is to 25 %. If the voltage is not overstated but, on the contrary, sags, a stabilizer is needed, for example the AVR-L (AVR3LS) at 70–140 kVA with 3 % accuracy.
Request a price and lead time
The manufacturer iVolt — voltage optimizer. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How much electricity does the iVolt optimizer save?
Savings reach 25 % and depend on how much the mains voltage is above what the equipment needs. Payback is usually 2–3 years.
What is the efficiency of the iVolt voltage optimizer?
The efficiency exceeds 99.4 % at full load, so the unit's own losses are small compared with the savings obtained.
How does a voltage optimizer differ from a stabilizer?
A stabilizer raises and lowers the voltage to nominal, while the iVolt first of all lowers it to a level sufficient for the equipment in order to reduce consumption. It also stabilizes the output, making more than 3000 measurements per second.
How to check the actual savings from the iVolt?
The built-in IRT Energy Monitor records the consumption of the site, and its data is used to compare costs before and after installation.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.