ComEC energy saving device 63–400 A
Country: · Model: ComEC
A compact voltage optimization device rated 63–400 A for commercial facilities. It regulates all three phases with an output of 210–254 V (L-N) or 364–440 V (L-L) and ±1 % accuracy. It has an on-board display and optional cloud monitoring.
- Rated current
- 63–400 A
- Regulation
- three-phase
- Output voltage
- 210–254 V (L-N) / 364–440 V (L-L)
- Accuracy
- ±1 %
Technical specifications
| Rated current | 63–400 A |
|---|---|
| Regulation | three-phase |
| Output voltage | 210–254 V (L-N) / 364–440 V (L-L) |
| Accuracy | ±1 % |
| Overload | 200 % 2 min |
| Protection | electronic automatic and emergency manual bypass |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
Regulation is three-phase and the output stays within 210–254 V phase to neutral. The ±1 % accuracy is wider than the ±0,5 % of the senior models and matches the commercial facilities the device is made for. A 200 % overload for 2 min covers short inrush currents. Protection consists of an electronic automatic bypass and an emergency manual bypass, so the load can stay on mains voltage during servicing. The device state is shown on the on-board display, and cloud monitoring is connected when needed. The line output is 364–440 V (L-L) and the phase output 210–254 V (L-N).
How to choose
Select the model by the rated load current within 63–400 A. Leave a margin based on the 200 % overload for 2 min if inrush currents are noticeable. If ±0,5 % accuracy is needed, look at the ESL-5, 45–250 kVA, or the static Aquarius, 10–120 kVA. For large industrial feeders up to 4000 kVA the Sirius advance is intended, and the Odyssey, 80–4000 kVA, performs double conversion. The rated current is given in amperes, so the load power is first converted to current at the mains voltage.
Request a price and lead time
ComEC energy saving device 63–400 A. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What current is the ComEC device rated for?
The rated current is 63–400 A with three-phase regulation.
What are the output voltage and accuracy of the ComEC?
The output is 210–254 V (L-N) or 364–440 V (L-L) with ±1 % accuracy.
What overload can the device withstand?
An overload of 200 % for 2 min.
Which bypasses does the ComEC have?
An electronic automatic bypass and an emergency manual bypass.
Can the ComEC be monitored remotely?
Yes, optional cloud monitoring is available, and on site the on-board display shows the state.