Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

VOLTAGE STABILIZERS

ComEC energy saving device 63–400 A

A compact voltage optimization device rated 63–400 A for commercial facilities. It regulates all three phases with an output of 210–254 V (L-N) or 364–440 V (L-L) and ±1 % accuracy. It has an on-board display and optional cloud monitoring.

Rated current
63–400 A
Regulation
three-phase
Output voltage
210–254 V (L-N) / 364–440 V (L-L)
Accuracy
±1 %

Technical specifications

Rated current63–400 A
Regulationthree-phase
Output voltage210–254 V (L-N) / 364–440 V (L-L)
Accuracy±1 %
Overload200 % 2 min
Protectionelectronic automatic and emergency manual bypass

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Regulation is three-phase and the output stays within 210–254 V phase to neutral. The ±1 % accuracy is wider than the ±0,5 % of the senior models and matches the commercial facilities the device is made for. A 200 % overload for 2 min covers short inrush currents. Protection consists of an electronic automatic bypass and an emergency manual bypass, so the load can stay on mains voltage during servicing. The device state is shown on the on-board display, and cloud monitoring is connected when needed. The line output is 364–440 V (L-L) and the phase output 210–254 V (L-N).

How to choose

Select the model by the rated load current within 63–400 A. Leave a margin based on the 200 % overload for 2 min if inrush currents are noticeable. If ±0,5 % accuracy is needed, look at the ESL-5, 45–250 kVA, or the static Aquarius, 10–120 kVA. For large industrial feeders up to 4000 kVA the Sirius advance is intended, and the Odyssey, 80–4000 kVA, performs double conversion. The rated current is given in amperes, so the load power is first converted to current at the mains voltage.

Request a price and lead time

ComEC energy saving device 63–400 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What current is the ComEC device rated for?

The rated current is 63–400 A with three-phase regulation.

What are the output voltage and accuracy of the ComEC?

The output is 210–254 V (L-N) or 364–440 V (L-L) with ±1 % accuracy.

What overload can the device withstand?

An overload of 200 % for 2 min.

Which bypasses does the ComEC have?

An electronic automatic bypass and an emergency manual bypass.

Can the ComEC be monitored remotely?

Yes, optional cloud monitoring is available, and on site the on-board display shows the state.

Similar products

Voltage stabilizers

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.