Ecostab — voltage optimizers for energy saving, 8–2800 kVA
Country: Italy · Model: Ecostab
Ecostab voltage optimizers for 8–2800 kVA reduce the energy consumption of enterprises. They are built on the Sterostab stabilizer technology and made in single-phase M and three-phase T/Y versions. Accuracy is ±1 % RMS and efficiency is above 98.5 %.
- Power
- 8–2800 kVA, single-phase M and three-phase T/Y
- Accuracy
- ±1 % RMS
- Efficiency
- > 98.5 %
- Overload
- 10× 10 ms, 5× 6 s, 2× 1 min
Technical specifications
| Power | 8–2800 kVA, single-phase M and three-phase T/Y |
|---|---|
| Accuracy | ±1 % RMS |
| Efficiency | > 98.5 % |
| Overload | 10× 10 ms, 5× 6 s, 2× 1 min |
| Distortion | ≤ 0.2 % |
| Protection class | IP00, IP21, IP54 (indoor/outdoor) |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The basis is the Sterostab stabilizer technology, so the voltage is regulated with the same accuracy of ±1 % RMS. The main purpose of the unit is to reduce the energy consumption of an enterprise. Efficiency exceeds 98.5 % and distortion does not exceed 0.2 %, so the optimizer's own losses are small. Short overloads are tolerated at 10× for 10 ms, 5× for 6 s and 2× for 1 min. The enclosure is offered with protection classes IP00, IP21 and IP54, for indoor and outdoor installation. Single-phase units are designated M and three-phase units T or Y.
How to choose
First determine the network type. The M version suits a single-phase network and T or Y a three-phase one. Then select the power within 8–2800 kVA and the protection class for the installation place. If a wider power range is needed, take Ecobuck at 5–4000 kVA, where distortion is likewise not above 0.2 %. When voltage stabilization matters more than saving, look at Ministab / Sterostab M, T or Y.
Request a price and lead time
Ecostab — voltage optimizers for energy saving, 8–2800 kVA. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the power range of Ecostab and which versions exist?
The power range is 8–2800 kVA. Single-phase versions are designated M and three-phase versions T or Y.
What overload can Ecostab withstand?
10× for 10 ms, 5× for 6 s and 2× for 1 min.
What are the distortion level and efficiency of the optimizer?
Distortion is not above 0.2 % and efficiency is above 98.5 %.
Which protection classes are available?
IP00, IP21 and IP54, for indoor and outdoor installation.
How does Ecostab differ from a Sterostab stabilizer?
Ecostab is built on the Sterostab technology but is meant to reduce energy consumption rather than for tight stabilization. Accuracy is ±1 % RMS.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.