Q 3000 / Q 3000 plus plasma system 20–300 A for digitalized production

The Q 3000 plasma source cuts with a current of 20–300 A at 100 % duty cycle and 40 °C and marks with a current of 5–60 A. It cuts structural steel in the range of 0.5–60 mm, and the maximum thickness is 80 mm. It is installed on CNC gantry machines and robotic systems.

Cutting current (100 % duty cycle, 40 °C)
20–300 A
Marking current
5–60 A
Power consumption
72 kVA
Fuse
125 A (slow-blow)

Technical specifications

Cutting current (100 % duty cycle, 40 °C)20–300 A
Marking current5–60 A
Power consumption72 kVA
Fuse125 A (slow-blow)
Mains voltage380–400, 415–440, 440–480 V, 50/60 Hz
Structural steelrecommended 0.5–60 mm, max. 80 mm, piercing 50 mm
Stainless steelmax. 60 mm (Q-Gas O2) / 80 mm (Q-Gas), piercing 30/50 mm
Aluminiummax. 60/80 mm, piercing 40/50 mm
GasesQ-Gas O2, Q-Gas
Piercingextended by ProPierce technology (with Q-Gas)
Automationcompatible with Q-Torch Auto Change

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The Q series is intended for digitalized and automated production. The source, including the Q 3000 plus version, cuts structural and stainless steel and aluminium, and also marks parts. It works on the gas combinations Q-Gas O2 and Q-Gas. For structural steel, piercing reaches 50 mm with both gases. Stainless steel is cut up to 60 mm with Q-Gas O2 (piercing 30 mm) and up to 80 mm with Q-Gas (piercing 50 mm), and aluminium up to 60 mm (piercing 40 mm) and up to 80 mm (piercing 50 mm) respectively. With Q-Gas, piercing is extended by ProPierce technology. The mains is 380–400, 415–440 or 440–480 V, 50/60 Hz; the power consumption is 72 kVA, with a 125 A slow-blow fuse, so the supply line is designed for exactly these values. For automatic replacement of torch heads, the system is combined with Q-Torch Auto Change, which the manufacturer states as compatible with the Q and iQ series.

How to choose

The upper current limit here is 300 A. If 150 A is enough, take iQ 1500, and if 450 A is needed, choose iQ 4500. In cutting parameters Q 3000 corresponds to iQ 3000. For machine cutting of 35–400 A Smart Focus is suitable, for precision cutting of 10–600 A HiFocus neo, and for 60–200 A with CNC, a robot or by hand K 200.

Request a price and lead time

Q 3000 / Q 3000 plus plasma system 20–300 A for digitalized production. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What steel thickness does Q 3000 cut?

Structural steel is recommended to be cut in the range of 0.5–60 mm, maximum 80 mm, piercing up to 50 mm.

What are the marking and cutting currents?

Cutting 20–300 A at 100 % duty cycle and 40 °C, marking 5–60 A.

What power supply does Q 3000 need?

Mains of 380–400, 415–440 or 440–480 V, 50/60 Hz, power consumption 72 kVA, a 125 A slow-blow fuse.

Which gases does the system use?

Q-Gas O2 and Q-Gas. Stainless steel with Q-Gas is cut up to 80 mm, with Q-Gas O2 up to 60 mm.

Can automatic torch replacement be connected?

Yes, the system is compatible with Q-Torch Auto Change, which is stated for the Q and iQ series.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.