Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

MATERIALS, ADHESIVES AND COATINGS

LOCTITE EA 9394 / 9394.2 / 9395 / 9396 / 9390 AERO (Hysol) high-temperature cold-cure epoxy pastes and laminating resins

A two-part thixotropic cold-cure epoxy paste that keeps its strength up to 177 °C and is used for bonding metals, honeycombs and composites, potting and liquid shim. Shear reaches 28.9 MPa at 25 °C. The family also includes low-viscosity laminating resins EA 9396 and EA 9390.

EA 9394
2K thixotropic paste; MMM-A-132 Rev B Type I Class 3 Form 3 Group 1; operating temperature 177 °C; A:B = 100:17 by weight; pot life 90 min (450 g); cure 3–5 days at 25 °C or 1 h at 66 °C
EA 9394 shear (ASTM D1002)
22.7 MPa at −55 °C; 28.9 MPa at 25 °C; 20.7 MPa at 82 °C; 8.3 MPa at 177 °C
EA 9394 bulk properties
tensile strength 46.0 MPa; modulus 4237 MPa; compression 68.9 MPa; dry Tg 78 °C; mixed density 1.36 g/ml
Variants
EA 9394S (in Semkit), EA 9394.2 (fast cure), EA 9394/C-2 (hot cure, high operating temperature), EA 9395 (non-metallic filler)

Technical specifications

EA 93942K thixotropic paste; MMM-A-132 Rev B Type I Class 3 Form 3 Group 1; operating temperature 177 °C; A:B = 100:17 by weight; pot life 90 min (450 g); cure 3–5 days at 25 °C or 1 h at 66 °C
EA 9394 shear (ASTM D1002)22.7 MPa at −55 °C; 28.9 MPa at 25 °C; 20.7 MPa at 82 °C; 8.3 MPa at 177 °C
EA 9394 bulk propertiestensile strength 46.0 MPa; modulus 4237 MPa; compression 68.9 MPa; dry Tg 78 °C; mixed density 1.36 g/ml
VariantsEA 9394S (in Semkit), EA 9394.2 (fast cure), EA 9394/C-2 (hot cure, high operating temperature), EA 9395 (non-metallic filler)
LaminatingEA 9396 (low viscosity, cold cure), EA 9390 (hot/wet strength), EA 956; open time up to 8 h
Resistanceafter 7 days in water, IPA, hydraulic fluid, JP-4 — 27.6–28.9 MPa
PackagingSemkit, cartridges, kits from grams to 55 gallons

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The base paste EA 9394 is qualified to MMM-A-132 Rev B Type I Class 3 Form 3 Group 1 and by many OEMs, has low toxicity and long pot life. The mixing ratio is 100:17 by weight, and the mixed viscosity is about 160 Pa·s. The pot life of a 450 g mass is 90 minutes at 25 °C, and more than 450 g must not be mixed because of dangerous heating. Cure takes 3–5 days at 25 °C with handling strength after 24 hours, or 1 hour at 66 °C for small masses. The cured resin has tensile strength 46.0 MPa, modulus 4237 MPa, compression 68.9 MPa, Shore D hardness 88 and a dry Tg of 78 °C.

How to choose

The choice depends on the cure schedule and the filler. EA 9394S comes in Semkit cartridges with reduced thixotropy, EA 9394.2 cures fast, EA 9394/C-2 is hot cure with a high operating temperature, and EA 9395 has a non-metallic filler. For wet layup and composite repair, take the low-viscosity resins EA 9396, EA 9390 (high strength in hot wet condition) and EA 956 with an open time of up to 8 hours.

Request a price and lead time

LOCTITE EA 9394 / 9394.2 / 9395 / 9396 / 9390 AERO (Hysol) high-temperature cold-cure epoxy pastes and laminating resins. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the shear strength of EA 9394 at different temperatures?

On 2024-T3 aluminum per ASTM D1002 it is 22.7 MPa at −55 °C, 28.9 MPa at 25 °C, 20.7 MPa at 82 °C, 15.8 MPa at 121 °C and 8.3 MPa at 177 °C.

What is the operating temperature of EA 9394 paste?

177 °C, with shear strength retained at 6.9 MPa.

Is the paste resistant to fluids?

After 7 days in water, isopropyl alcohol, hydraulic fluid and JP-4 fuel the strength is 27.6–28.9 MPa.

What is the mixing ratio of EA 9394?

100:17 by weight. Volumetric dosing is not recommended for structural joints.

How much paste can be mixed at one time?

No more than 450 g, because a larger mass heats up dangerously. The pot life of such a mass is 90 minutes.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.