C-RAM FT-10 and HFP ferrite tiles and hybrid absorbers for EMC chambers, 20–30 MHz … 40 GHz

C-RAM FT-10 is a thin 100×100×6.3 mm tile of sintered ferrite ceramic for lining EMC chambers. The tile alone works in the 20 MHz – 1.5 GHz range, and with HFP hybrid absorbers the range reaches 40 GHz. It is used where foam pyramids would be too tall.

FT-10 material
sintered ferrite ceramic, no outgassing (suitable for vacuum)
Tile dimensions
100×100×6.3 mm, central hole 10 mm; 300×300 mm panels on plywood with metal facing
Weight
324 g per tile = 32.4 kg/m²
FT-10 reflectivity
−18 dB 30 MHz; −25 dB 100 MHz; −30 dB 200 MHz; −25 dB 400 MHz; −20 dB 600 MHz; −12 dB 1 GHz; −9 dB 1.5 GHz

Technical specifications

FT-10 materialsintered ferrite ceramic, no outgassing (suitable for vacuum)
Tile dimensions100×100×6.3 mm, central hole 10 mm; 300×300 mm panels on plywood with metal facing
Weight324 g per tile = 32.4 kg/m²
FT-10 reflectivity−18 dB 30 MHz; −25 dB 100 MHz; −30 dB 200 MHz; −25 dB 400 MHz; −20 dB 600 MHz; −12 dB 1 GHz; −9 dB 1.5 GHz
Operating rangeFT: 20 MHz – 1.5 GHz (TDS: 30 MHz – 2 GHz); HFP: 20/26 MHz – 40 GHz
Temperatureup to the Curie point 203 °F (95 °C)
HFPhollow matched hybrid absorbers 12–48 inches high on top of the FT tile
Application standardsANSI C63.4 (radiated emissions), IEC 1000-4-3 (immunity)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The tile has a central hole of 10 mm and a weight of 324 g, that is 32.4 kg per square meter of lining. According to bulletin 390-5, the reflectivity is −18 dB at 30 MHz, −25 dB at 100 MHz, −30 dB at 200 MHz, −25 dB at 400 MHz, −20 dB at 600 MHz, −12 dB at 1 GHz and −9 dB at 1.5 GHz. It is mounted only on a conductive surface, with epoxy or silicone adhesive or with self-tapping screws and plastic washers through the hole. For large areas there are 300×300 mm panels on plywood with metal facing. The ceramic does not outgas and works up to the Curie point of 203 °F (95 °C), but it is hard to cut, so gaps are left in the corners. HFP are hollow matched polyurethane foam pyramids from 12 to 48 inches high, and the combination of FT and HFP covers the range from 20–26 MHz to 40 GHz. The application complies with ANSI C63.4 and IEC 1000-4-3, and the tile is used in pre-scan, 3 m and 10 m chambers.

How to choose

FT-10 tiles are used in the lower part of the range up to 1.5 GHz, and above that HFP 12 to 48 inches high are added. The HFP height is chosen by the lowest frequency at which reflectivity is needed. The 300×300 mm panels are convenient for large areas because the tiles are already glued to the plywood. The dimensions are metric, so projects in feet are recalculated.

Request a price and lead time

C-RAM FT-10 and HFP ferrite tiles and hybrid absorbers for EMC chambers, 20–30 MHz … 40 GHz. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the weight of an FT-10 tile?

324 g, or 32.4 kg per square meter of lining.

What is the reflectivity of FT-10 at 100 MHz?

−25 dB, and −30 dB at 200 MHz.

Is the tile suitable for vacuum installations?

Yes, the ferrite ceramic does not outgas.

How is the FT-10 tile mounted?

Only on a conductive surface, with epoxy or silicone adhesive or with self-tapping screws and plastic washers through the 10 mm central hole.

What temperature does the ferrite tile work up to?

Up to the Curie point of 203 °F (95 °C).

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.