Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

MATERIALS, ADHESIVES AND COATINGS

C-RAM SFC-HC / HC / CB-HC / CF honeycomb and cellular-glass high-power absorbers (up to 80 W/inch² with airflow, CF up to +343 °C)

C-RAM SFC-HC, HC, CB-HC and CF are absorbers on a rigid frame of phenolic honeycomb and cellular glass for powers up to 80 W/inch² with airflow. CF bricks work up to +343 °C. The materials do not melt and let cooling air through.

SFC-HC
pyramids of phenolic honeycomb; heights 3¼–24 inches (82–610 mm), 48–72 inches on request; 24×24 inch panel
SFC-HC power
10 W/inch² without airflow; 20/40/60/80 W/inch² at an air speed of 200/300/400/600 ft/min (10 GHz)
SFC-HC range
from 500 MHz
HC (flat sheets)
Nomex/phenolic or glass/phenolic honeycomb; sheets 12×12 or 24×24 inches, thickness 0.5–4.0 inches; cell 3/16 inch

Technical specifications

SFC-HCpyramids of phenolic honeycomb; heights 3¼–24 inches (82–610 mm), 48–72 inches on request; 24×24 inch panel
SFC-HC power10 W/inch² without airflow; 20/40/60/80 W/inch² at an air speed of 200/300/400/600 ft/min (10 GHz)
SFC-HC rangefrom 500 MHz
HC (flat sheets)Nomex/phenolic or glass/phenolic honeycomb; sheets 12×12 or 24×24 inches, thickness 0.5–4.0 inches; cell 3/16 inch
HCGRgraded sheets: 0.5 inch — −15 dB at 10–18 GHz; 0.75 — at 8–18 GHz; 1.0 — at 6–18 GHz
HCGI / HCUIsheets with specified insertion loss up to 20 / 30 dB/inch
CFcellular glass bricks 12×18 inches, 2 or 3 inches; −70…+650 °F (−57…+343 °C); 10 W/inch² (25 W/inch² at 100 ft/min); CF-2: 14 dB at 1–2.5 GHz, 17 dB at 3.5–14 GHz
Operating temperature HC/SFC-HCup to 400 °F (204 °C)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

SFC-HC are phenolic honeycomb pyramids 3¼–24 inches (82–610 mm) high on a 24-inch panel, and for 48 and 72 inches they are assembled from sections. Without airflow they dissipate 10 W/inch², and at air speeds of 200, 300, 400 and 600 ft/min the permissible power rises to 20, 40, 60 and 80 W/inch² (tested at 10 GHz). Flat HC sheets made of Nomex/phenolic honeycomb measure 12×12 or 24×24 inches, are 0.5–4.0 inches thick and have a 3/16 inch cell. HCGR with graded impregnation gives at least −15 dB: the 0.5 inch sheet at 10–18 GHz, 0.75 at 8–18 GHz, 1.0 at 6–18 GHz. HCGI and HCUI are made with insertion loss up to 20 and 30 dB/inch. CF are cellular glass bricks of 12×18 inches, 2 or 3 inches thick, which work from −70 to +650 °F (−57 to +343 °C) and dissipate 10 W/inch², or 25 W/inch² with 100 ft/min airflow. CF-2 gives 14 dB at 1–2.5 GHz and 17 dB at 3.5–14 GHz.

How to choose

SFC-HC pyramids are used for chambers and test stands with high RF power, flat HC sheets for radomes and covers, and CF where the highest temperature is needed. For foam versions, ventilated and all-weather, there are C-RAM EVA, SFC-MP, ODP and CFC. The corner of the chamber is filled with CB-HC blocks.

Request a price and lead time

C-RAM SFC-HC / HC / CB-HC / CF honeycomb and cellular-glass high-power absorbers (up to 80 W/inch² with airflow, CF up to +343 °C). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does SFC-HC withstand?

10 W/inch² without airflow, and from 20 to 80 W/inch² at an air speed of 200–600 ft/min.

What is the operating temperature of CF bricks?

From −57 to +343 °C, or from −70 to +650 °F.

What is the thickness of flat HC sheets?

0.5–4.0 inches, with a sheet size of 12×12 or 24×24 inches.

How are CF bricks laid?

They are cut with a band saw and laid in a self-supporting wall or on mortar.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.