MATERIALS, ADHESIVES AND COATINGS
ColourTherm CT / CTIP180 / PL368 / 650 range thermochromic temperature-indicating and high-temperature marking paints
Country: United Kingdom · Model: ColourTherm CT, CTIP180, PL368, 650 Range
ColourTherm thermochromic indicator paints that change color at a set temperature from 80 to 440 °C, and marking paints for heat-resistant steels. Irreversible paints record the temperature history of a part and reveal hot spots and failure of internal insulation. They are used in chemical, petrochemical and aviation equipment.
- ColourTherm irreversible
- CT-80, CT-115-Rev1, CT-140, CT-150, CT-160, CT-165-R1, CT-IP180, CT-225, CT-400, CT-410, CT-440; first color change 80–440 °C, subsequent up to 560 °C
- Principle
- chemical change of solid components when heated for ≥ 10 min; irreversible
- Thinner
- CT-8590Xl
- CTIP180
- temperature-indicating paint for refinery reactors
Technical specifications
| ColourTherm irreversible | CT-80, CT-115-Rev1, CT-140, CT-150, CT-160, CT-165-R1, CT-IP180, CT-225, CT-400, CT-410, CT-440; first color change 80–440 °C, subsequent up to 560 °C |
|---|---|
| Principle | chemical change of solid components when heated for ≥ 10 min; irreversible |
| Thinner | CT-8590Xl |
| CTIP180 | temperature-indicating paint for refinery reactors |
| Reversible | ColourTherm low-temperature reversible |
| PL368 | heating and corrosion identification paint up to 600 °C |
| 650 Range | inorganic marking paints for heat-resistant steels (IP9091, PL149–PL168-R1); PL155R1 close to Fed Std 595 22510; PL111-R1, yellow silicone-epoxy-melamine |
| Customs codes (for reference) | |
| NSN (NATO Stock Number) | 8010-99-834-4616 (per the manufacturer's document, to be confirmed by packaging) |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
Irreversible paints work through a chemical change of solid components. Heating for about 10 minutes to the set temperature or above changes the color permanently, and with prolonged heating the transition is possible at a somewhat lower temperature. Before the first transition the paints are thermally stable. The range includes the CT-80 (80, 240, 295 °C), CT-115-Rev1 (115, 145, 300), CT-140 (140, 316, 360), CT-150 (150, 240, 310), CT-160 (160, 190, 250), CT-165-R1 (165, 180, 205), CT-IP180 (180, 310), CT-225 (225, 235, 285), CT-400 (400, 520, 560), CT-410 (410, 440, 560) and CT-440 (440). The thinner is CT-8590Xl. The CTIP180 with transitions at 180 and 300 °C is often taken for refinery reactors. There is also a reversible low-temperature paint. The PL368 identifies heating and corrosion up to 600 °C. The inorganic marking paints of the 650 series (IP9091, PL149, PL150, PL151-R1, PL152-R1, PL153, PL155-R1, PL167-R1, PL168-R1) are intended for heat-resistant steels, and the PL155R1 is close to Fed Std 595 22510. The PL111-R1 is a yellow silicone-epoxy-melamine.
How to choose
First determine the temperature of the first transition. For low temperatures take the CT-80 or CT-115-Rev1, for 180 °C on reactors the CTIP180, for the highest the CT-400, CT-410 or CT-440. If what is needed is not heat tracking but marking of parts made of heat-resistant steels, see the 650 series or PL111-R1. Heating together with corrosion up to 600 °C is tracked by the PL368.
Request a price and lead time
ColourTherm CT / CTIP180 / PL368 / 650 range thermochromic temperature-indicating and high-temperature marking paints. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
How long must it be heated for an irreversible paint to change color?
About 10 minutes to the set temperature or above. With prolonged heating the change is possible at a somewhat lower temperature.
What transitions does the CTIP180 paint have?
180 and 300 °C. It is often used on refinery reactors.
What is the range of first transition temperatures in the CT range?
From 80 °C in the CT-80 to 440 °C in the CT-440, and subsequent transitions reach 560 °C.
What should be used to thin the irreversible ColourTherm paints?
The thinner CT-8590Xl.
What is the PL368 intended for?
For identification of heating and corrosion when resistance up to 600 °C and to chemicals is needed.
Similar products
C-RAM RGD / KR / KRS / KFS / VHPC-RAM RGD / KR / KRS / KFS / VHP rigid and cast iron-epoxy and iron-silicone absorbers, radar-absorbing paints
C-RAM EVA / SFC-MP / ODP / CFCC-RAM EVA / SFC-MP / ODP / CFC higher-power, ventilated, all-weather and cleanroom pyramidal absorbers
UV15DC80 / UV22DC80-1 / UV26DC / LED401 / LED422DC90Dual-Cure Systems (UV/LED + Heat) for Shadow Areas
EP21TP-2NV / EP21TPFL-1 / EP21TPHT / EP30D-7 / Super Gel 9Epoxy-Polysulfide and Urethane-Modified Flexible SystemsREQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.