Lynx Smart BMS / Lynx Smart BMS NG — battery management system 500/1,000 A

The Lynx Smart BMS is rated 500 or 1,000 A and slots straight into the Lynx distribution busbar. It is the most capable BMS in the maker’s range and works with Lithium Battery Smart and Lithium NG batteries in stationary and marine systems with high currents.

Current
500 A and 1,000 A
Functions
BMS, contactor, shunt monitor, pre-alarm
Compatibility
Lithium Battery Smart / Lithium NG
Communication
Bluetooth, GX, VRM

Technical specifications

Current500 A and 1,000 A
FunctionsBMS, contactor, shunt monitor, pre-alarm
CompatibilityLithium Battery Smart / Lithium NG
CommunicationBluetooth, GX, VRM
Customs codes (for reference)
HS code8537.10
UKTZED code (Ukraine)8537109890
CN code (EU)85371098

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The enclosure combines the BMS, a power contactor and a battery shunt monitor, so no separate monitor or main disconnect goes into the circuit. The contactor disconnects the bank from loads and chargers when cells go outside safe limits. Before disconnecting, the system sends a pre-alarm so the operator can reduce the load or start a generator. Lynx modules bolt together by their busbars, and the BMS becomes part of the same assembly as the load fuses. The NG version is for Lithium NG batteries, the standard one for Lithium Battery Smart. Settings and data are available over Bluetooth, through a GX controller and on the VRM portal, which shows cell voltages, current and state of charge.

How to choose

The rating follows the total current of inverters and loads on the busbar. Up to 500 A the smaller version is enough, while several 48 V inverters or a heavy 12 V load call for 1,000 A. A small 12 V system in a van or boat is easier with the Smart BMS CL 12-100 or Smart BMS 12-200 and their alternator current limiter. If a bank of up to 1,500 Ah at 48 V only feeds MultiPlus or Quattro units over VE.Bus, the VE.Bus BMS without a contactor will do.

Request a price and lead time

Lynx Smart BMS / Lynx Smart BMS NG — battery management system 500/1,000 A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What current ratings does the Lynx Smart BMS come in?

500 A and 1,000 A, chosen by the total current on the busbar.

Which batteries does the Lynx Smart BMS work with?

With Lithium Battery Smart and Lithium NG batteries.

Does the Lynx Smart BMS have a built-in shunt?

Yes, the enclosure contains a shunt monitor and a contactor rated 500 or 1,000 A.

What does the pre-alarm in the Lynx Smart BMS do?

It warns that the contactor is about to disconnect the bank, so the operator has time to cut the load.

Can the Lynx Smart BMS be monitored remotely?

Yes, a GX controller sends the data to the VRM portal, and near the battery it is visible over Bluetooth.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.