Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BATTERY MANAGEMENT SYSTEMS (BMS)

MG Master HV — BMS for high-voltage battery systems up to 900 V

Master HV manages MG high-voltage battery strings from 48 to 900 V DC and switches them with a contactor of up to 500 A. A separate master is installed for each series string, so system capacity is increased by parallel strings.

Versions
Master HV 300 / 500 / 500 G2; 19-inch 750 V / 160 A
Max. voltage
900 V DC (19″ — 300–750 V DC)
Main contactor current
up to 500 A
Supply voltage
18–32 V DC

Technical specifications

VersionsMaster HV 300 / 500 / 500 G2; 19-inch 750 V / 160 A
Max. voltage900 V DC (19″ — 300–750 V DC)
Main contactor currentup to 500 A
Supply voltage18–32 V DC
CommunicationCAN Bus M12
Protection ratingIP65 (500 G2), IP30 (19″)
CertificatesDNV-GL, Lloyd's, IEC-EN 62619 (ES-TRIN)
Customs code (manufacturer's)8537109199

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The unit performs protection, control, monitoring and energy metering of the string. The range includes Master HV 300, 500 and 500 G2, as well as a 19-inch rack version of 750 V and 160 A. The rack model works in the range of 300–750 V DC, the others up to 900 V DC. The electronics are powered from 18–32 V DC, and data is exchanged over a CAN Bus with M12 connectors. The 500 G2 version has an IP65 case for engine rooms and machinery, while the 19-inch IP30 version is installed only in a closed rack. The unit has DNV-GL and Lloyd's approvals and complies with IEC-EN 62619 (ES-TRIN); the customs code according to the manufacturer is 8537109199.

How to choose

The choice between versions depends on the string voltage, current and installation place. For systems of up to 750 V in a 19-inch cabinet the 160 A rack model is convenient; for vessels and mobile machinery the 500 A G2 with IP65. If the battery is low-voltage, 12–96 V, and currents reach 1000 A, a Master LV is needed.

Request a price and lead time

MG Master HV — BMS for high-voltage battery systems up to 900 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What maximum voltage does MG Master HV support?

Up to 900 V DC, and the 19-inch version works in the range of 300–750 V DC.

How many Master HV units are needed for a system with several strings?

One master per series string; capacity is increased by connecting strings in parallel, each with its own unit.

Does Master HV have marine certificates?

Yes, the unit has DNV-GL and Lloyd's approvals and complies with IEC-EN 62619 (ES-TRIN).

What power supply does the Master HV BMS need?

The unit electronics are powered from 18–32 V DC, and communication with the modules goes over a CAN Bus with M12 connectors.

What is the protection rating of Master HV 500 G2?

IP65, whereas the 19-inch version has IP30 and is mounted in a closed rack.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.