Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

CHARGE CONTROLLERS AND EMS

Energy Controller Pro L — battery park controller (EZA/PPC)

Energy Controller Pro L runs a battery park of 5 MWh and up as one plant and is certified to VDE-AR-N 4110 and 4120 for connection to medium- and high-voltage grids. In German terms it is an EZA controller, internationally a PPC, sitting between the grid operator, the energy trader and the park equipment.

Application
BESS parks and projects above 5 MWh
Certification
VDE-AR-N 4110 and 4120
Functions
grid operator interface, execution of trading schedules, co-location
Security
IoT gateway with Endian firewall/VPN

Technical specifications

ApplicationBESS parks and projects above 5 MWh
CertificationVDE-AR-N 4110 and 4120
Functionsgrid operator interface, execution of trading schedules, co-location
SecurityIoT gateway with Endian firewall/VPN
ComponentsWAGO
Customs codes (for reference)
HS code9032.89
UKTZED code (Ukraine)9032890000
CN code (EU)90328900

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

In real time the controller processes grid operator requirements, trader schedules and battery and inverter data, then dispatches power setpoints. The co-location function is needed when the BESS shares a grid connection point with a PV or wind farm and total export is capped. External communication runs through an IoT gateway with an Endian firewall and VPN, so remote access does not expose the park directly to the internet. The hardware is built on WAGO components, a common industrial base for automation cabinets. The controller works with equipment from different manufacturers, so a park can mix batteries and PCS of several brands.

How to choose

Pro L is the choice where the grid operator demands a controller certified to VDE-AR-N 4110 or 4120 and the park trades on the market by schedule, usually from 5 MWh. A single commercial site focused on self-consumption and zero export is served by Energy Manager with software 3.2. In a park the controller is combined with TALLON or Sunwoda NoahX containers at 2.5 MW each, or with Samsung Battery Box.

Request a price and lead time

Energy Controller Pro L — battery park controller (EZA/PPC). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which projects need the Energy Controller Pro L?

BESS parks and projects above 5 MWh that must follow grid operator requirements and trading schedules.

Which standards is the Energy Controller Pro L certified to?

VDE-AR-N 4110 and 4120, the German technical rules for connection to medium- and high-voltage grids.

Does the Energy Controller Pro L work with third-party equipment?

Yes, it is compatible with batteries and inverters of different brands and reads their data in real time.

How is remote access to the park controller secured?

Through the IoT gateway with an Endian firewall and VPN. The park is not exposed directly to the internet.

What does the co-location function of a park controller mean?

Joint operation of storage and generation at one grid connection point. The controller keeps total export within the permitted capacity.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.