NetMan and MultiCom — communication cards, sensors and monitoring panels for UPS
Country: Italy · Model: NetMan / MultiCom
NetMan and MultiCom communication cards, environmental sensors and remote panels connect a UPS or static transfer switch to an IT network, a building management system or industrial automation. The NetMan 208C network card runs on 10/100/1000 Mbit/s Ethernet. These devices carry remote monitoring and control, status signals, and temperature and humidity readings.
- NetMan 208C
- Ethernet 10/100/1000 Mbit/s; TCP/IP, HTTPS, SNMP, Modbus/TCP, BACnet/IP; LDAP/Active Directory, VMware ESXi/vCenter; IEC 62443-4-2 certified
- MultiCom 302 / 352 / 372
- Modbus/Jbus over RS232/RS485; serial port duplexer; additional RS232 with emergency and remote shutdown inputs
- MultiCom 384 / 392
- relay contacts and EPO input; 8 dry outputs and 4 inputs
- MultiCom 411 / 421
- Profibus DP (9.6 kbit/s – 12 Mbit/s) and PROFINET IO gateways
Technical specifications
| NetMan 208C | Ethernet 10/100/1000 Mbit/s; TCP/IP, HTTPS, SNMP, Modbus/TCP, BACnet/IP; LDAP/Active Directory, VMware ESXi/vCenter; IEC 62443-4-2 certified |
|---|---|
| MultiCom 302 / 352 / 372 | Modbus/Jbus over RS232/RS485; serial port duplexer; additional RS232 with emergency and remote shutdown inputs |
| MultiCom 384 / 392 | relay contacts and EPO input; 8 dry outputs and 4 inputs |
| MultiCom 411 / 421 | Profibus DP (9.6 kbit/s – 12 Mbit/s) and PROFINET IO gateways |
| Multi I/O | 8 inputs and 8 relay outputs, Modbus/Jbus over RS485 |
| MultiPanel | remote monitoring panel, 3 serial ports, 7 menu languages |
| Environmental sensors | up to 3 per NetMan 208/208C: −55…+125 °C, humidity 0–100 %, digital input/output |
| Slot Adapter | connects cards to a UPS without a slot via RS232; 10–30 V DC supply |
| Customs codes (for reference) | |
| HS code | 8517.62 |
| UKTZED code (Ukraine) | 8517620000 |
| CN code (EU) | 85176200 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
NetMan 208C speaks TCP/IP, HTTPS, SNMP, Modbus/TCP and BACnet/IP, works with LDAP/Active Directory and VMware ESXi/vCenter and is certified to IEC 62443-4-2. MultiCom 302, 352 and 372 output Modbus/Jbus over RS232/RS485, duplicate the serial port and add an RS232 port with emergency and remote shutdown inputs. MultiCom 384 and 392 carry relay contacts, an EPO input, 8 dry outputs and 4 inputs. The MultiCom 411 and 421 gateways link the UPS to Profibus DP at 9.6 kbit/s – 12 Mbit/s and to PROFINET IO. The Multi I/O module has 8 inputs and 8 relay outputs with Modbus/Jbus over RS485. The MultiPanel with 3 serial ports and a menu in 7 languages hangs in the control room. The Slot Adapter connects cards to a UPS without a slot via RS232 and runs on 10–30 V DC.
How to choose
Start with where the UPS data has to go. A server room or BMS needs only NetMan 208C, an old panel with no network takes MultiCom 384/392 dry contacts, and a plant floor with PLCs a MultiCom 411 or 421 gateway. Server shutdown runs in PowerShield³ (free for 1 UPS, licensed up to 32), and a fleet is pulled together in PowerNetGuard over SNMP (RFC 1628).
Request a price and lead time
NetMan and MultiCom — communication cards, sensors and monitoring panels for UPS. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which protocols does the NetMan 208C card support?
TCP/IP, HTTPS, SNMP, Modbus/TCP and BACnet/IP over 10/100/1000 Mbit/s Ethernet. The card is certified to IEC 62443-4-2.
How many environmental sensors can be connected to a NetMan 208?
Up to 3 sensors per NetMan 208/208C card. They measure temperature from −55 to +125 °C and humidity from 0 to 100 %.
How do I connect a UPS to Profibus or PROFINET?
Use the MultiCom 411 and 421 gateways. They handle Profibus DP at 9.6 kbit/s to 12 Mbit/s and PROFINET IO.
How do I shut down a UPS from an EPO signal?
Wire the dry contact of the stop button or fire panel to the EPO input of a MultiCom 384 or 392 card.
Similar products
REQUEST
Need a price, lead time or replacement?